A new ultrasonic transducer for improved contrast nonlinear imaging
Abstract
Second harmonic imaging has provided significant improvement in contrast detection over fundamental imaging. This improvement is a result of a higher contrast-to-tissue ratio (CTR) achievable at the second harmonic frequency. Nevertheless, the differentiation between contrast and tissue at the second harmonic frequency is still in many situations cumbersome and contrast detection remains nowadays as one of the main challenges, especially in the capillaries. The reduced CTR is mainly caused by the generation of second harmonic energy from nonlinear propagation effects in tissue, which hence obscures the echoes from contrast bubbles. In a previous study, we demonstrated theoretically that the CTR increases with the harmonic number. Therefore the purpose of our study was to increase the CTR by selectively looking to the higher harmonic frequencies. In order to be able to receive these high frequency components (third up to the fifth harmonic), a new ultrasonic phased array transducer has been constructed. The main advantage of the new design is its wide frequency bandwidth. The new array transducer contains two different types of elements arranged in an interleaved pattern (odd and even elements). This design enables separate transmission and reception modes. The odd elements operate at 2.8 MHz and 80% bandwidth, whereas the even elements have a centre frequency of 900 kHz with a bandwidth of 50%. The probe is connected to a Vivid 5 system (GE-Vingmed) and proper software is developed for driving. The total bandwidth of such a transducer is estimated to be more than 150% which enables higher harmonic imaging at an adequate sensitivity and signal to noise ratio compared to standard medical array transducers. We describe in this paper the design and fabrication of the array transducer. Moreover its acoustic properties are measured and its performances for nonlinear contrast imaging are evaluated in vitro and in vivo. The preliminary results demonstrate the advantages of such a transducer design for improved contrast detection.
Similar articles
-
Super harmonic imaging: a new imaging technique for improved contrast detection.Ultrasound Med Biol. 2002 Jan;28(1):59-68. doi: 10.1016/s0301-5629(01)00460-4. Ultrasound Med Biol. 2002. PMID: 11879953
-
Optimization of a phased-array transducer for multiple harmonic imaging in medical applications: frequency and topology.IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Mar;58(3):533-46. doi: 10.1109/TUFFC.2011.1837. IEEE Trans Ultrason Ferroelectr Freq Control. 2011. PMID: 21429845
-
Super-harmonic imaging: development of an interleaved phased-array transducer.IEEE Trans Ultrason Ferroelectr Freq Control. 2010;57(2):455-68. doi: 10.1109/TUFFC.2010.1426. IEEE Trans Ultrason Ferroelectr Freq Control. 2010. PMID: 20178912
-
[Improved endocardium imaging using modified transthoracic echocardiography with the second harmonic frequency (tissue harmonic imaging)].Herz. 1998 Dec;23(8):467-73. doi: 10.1007/BF03043753. Herz. 1998. PMID: 10023580 Review. German.
-
A Primer on the Physical Principles of Tissue Harmonic Imaging.Radiographics. 2015 Nov-Dec;35(7):1955-64. doi: 10.1148/rg.2015140338. Radiographics. 2015. PMID: 26562232 Review.
Cited by
-
Design and Fabrication of 1-D CMUT Arrays for Dual-Mode Dual-Frequency Acoustic Angiography Applications.IEEE Trans Ultrason Ferroelectr Freq Control. 2024 Jan;71(1):191-201. doi: 10.1109/TUFFC.2023.3342011. Epub 2024 Jan 9. IEEE Trans Ultrason Ferroelectr Freq Control. 2024. PMID: 38090855 Free PMC article.
-
Interleaved Array Transducer with Polarization Inversion Technique to Implement Ultrasound Tissue Harmonic Imaging.Sensors (Basel). 2020 Jul 14;20(14):3915. doi: 10.3390/s20143915. Sensors (Basel). 2020. PMID: 32674455 Free PMC article.
-
Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging.Sensors (Basel). 2014 Nov 4;14(11):20825-42. doi: 10.3390/s141120825. Sensors (Basel). 2014. PMID: 25375755 Free PMC article.
-
An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography.IEEE Trans Ultrason Ferroelectr Freq Control. 2020 Nov;67(11):2291-2302. doi: 10.1109/TUFFC.2020.3001221. Epub 2020 Jun 9. IEEE Trans Ultrason Ferroelectr Freq Control. 2020. PMID: 32746179 Free PMC article.
-
A Rapid Prototyping Method for Sub-MHz Single-Element Piezoelectric Transducers by Using 3D-Printed Components.Sensors (Basel). 2022 Dec 28;23(1):313. doi: 10.3390/s23010313. Sensors (Basel). 2022. PMID: 36616910 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources