Quick tour of fluorescence correlation spectroscopy from its inception
- PMID: 15447006
- DOI: 10.1117/1.1779234
Quick tour of fluorescence correlation spectroscopy from its inception
Abstract
Fluorescence correlation spectroscopy (FCS) was originally developed in the early 1970s as a way to measure the kinetics of chemical reactions under zero perturbation conditions. At its inception, the measurement was difficult due to experimental limitations and was primarily used during the 1970s and 1980s to characterize diffusion. More recently, as a result of technological advances, FCS measurements have become easier and more versatile. In addition to measurements of diffusion both in solution and in cells, FCS is now also used to measure not only chemical reaction kinetics but also extents of molecular aggregation, the dynamics of photophysical processes, conformational fluctuations, molecular interactions in solution and in cells, and has even found application as a pharmaceutical screening method. From its inception to the present, the contributions of Webb and his coworkers have had a central and defining role in the development and applications of FCS.
(c) 2004 Society of Photo-Optical Instrumentation Engineers.
Similar articles
-
Diffusion and segmental dynamics of rodlike molecules by fluorescence correlation spectroscopy.J Chem Phys. 2007 Aug 7;127(5):054904. doi: 10.1063/1.2753160. J Chem Phys. 2007. PMID: 17688361
-
A dynamic view of cellular processes by in vivo fluorescence auto- and cross-correlation spectroscopy.Methods. 2003 Jan;29(1):74-85. doi: 10.1016/s1046-2023(02)00291-8. Methods. 2003. PMID: 12543073 Review.
-
Diffusion and binding properties investigated by Fluorescence Correlation Spectroscopy (FCS).Curr Pharm Biotechnol. 2005 Oct;6(5):381-6. doi: 10.2174/138920105774370616. Curr Pharm Biotechnol. 2005. PMID: 16248811 Review.
-
Single-molecule photobleaching: Instrumentation and applications.J Biosci. 2018 Jul;43(3):447-454. J Biosci. 2018. PMID: 30002264
-
Cross-validating FRAP and FCS to quantify the impact of photobleaching on in vivo binding estimates.Biophys J. 2010 Nov 3;99(9):3093-101. doi: 10.1016/j.bpj.2010.08.059. Biophys J. 2010. PMID: 21044608 Free PMC article.
Cited by
-
Analysis of protein and lipid dynamics using confocal fluorescence recovery after photobleaching (FRAP).Curr Protoc Cytom. 2012 Oct;Chapter 2:Unit2.19. doi: 10.1002/0471142956.cy0219s62. Curr Protoc Cytom. 2012. PMID: 23042527 Free PMC article.
-
Flying kites on slippery slopes at Keystone. Symposium on Lipid Rafts and Cell Function.EMBO Rep. 2006 Nov;7(11):1089-93. doi: 10.1038/sj.embor.7400836. Epub 2006 Oct 20. EMBO Rep. 2006. PMID: 17057643 Free PMC article. No abstract available.
-
Fluorescence correlation spectroscopy and fluorescence cross-correlation spectroscopy.Wiley Interdiscip Rev Syst Biol Med. 2009 Sep-Oct;1(2):273-282. doi: 10.1002/wsbm.5. Wiley Interdiscip Rev Syst Biol Med. 2009. PMID: 20835996 Free PMC article. Review.
-
Kinetics of a single cross-bridge in familial hypertrophic cardiomyopathy heart muscle measured by reverse Kretschmann fluorescence.J Biomed Opt. 2010 Jan-Feb;15(1):017011. doi: 10.1117/1.3324871. J Biomed Opt. 2010. PMID: 20210485 Free PMC article.
-
Fluorescent correlation spectroscopy measurements with adaptive optics in the intercellular space of spheroids.Biomed Opt Express. 2014 Sep 29;5(10):3730-8. doi: 10.1364/BOE.5.003730. eCollection 2014 Oct 1. Biomed Opt Express. 2014. PMID: 25360385 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources