Optical coherence tomography of malignancy in hamster cheek pouches
- PMID: 15447019
- DOI: 10.1117/1.1783897
Optical coherence tomography of malignancy in hamster cheek pouches
Abstract
Optical coherence tomography (OCT)/optical Doppler tomography (ODT) provides real-time in vivo high-resolution (10-microm) imaging of tissues and real-time spatially resolved blood flow in microvasculature. Hamster cheek pouches with induced dysplasia and malignancies were imaged with OCT/ODT to assess the potential for application to airway malignancy. In 22 Golden Syrian hamsters, 0.5% 9,10-dimethyl-1,2-benzanthracene induces carcinogenesis over 10 weeks in right side cheek pouches; the left side three served as controls. The cheek pouches are imaged in vivo prior to sacrifice, and in vitro after excision, using a prototype 1310-nm broadband superluminescent diode based OCT/ODT device. Images are compared to standard histopathology. OCT imaging offers good resolution of the hamster cheek pouches to depths of 1 to 3 mm and paralleled histologic images. The feasibility of high-resolution functional imaging is demonstrated in this hamster cheek pouch tumor model. ODT accurately detects vascular change associated with carcinogenesis.
(c) 2004 Society of Photo-Optical Instrumentation Engineers.
Similar articles
-
Feasibility of three-dimensional optical coherence tomography and optical Doppler tomography of malignancy in hamster cheek pouches.Photomed Laser Surg. 2006 Jun;24(3):402-9. doi: 10.1089/pho.2006.24.402. Photomed Laser Surg. 2006. PMID: 16875451
-
Noninvasive imaging of oral premalignancy and malignancy.J Biomed Opt. 2005 Sep-Oct;10(5):051601. doi: 10.1117/1.2098930. J Biomed Opt. 2005. PMID: 16292949
-
Regional lymph node metastasis created by partial excision of carcinomas induced in hamster cheek pouch with 9,10-dimethyl-1,2-benzanthracene.J Dent Res. 1987 Nov;66(11):1673-9. doi: 10.1177/00220345870660111401. J Dent Res. 1987. PMID: 10872405
-
The hamster cheek pouch model of carcinogenesis and chemoprevention.Adv Exp Med Biol. 1992;320:63-7. doi: 10.1007/978-1-4615-3468-6_9. Adv Exp Med Biol. 1992. PMID: 1279957 Review. No abstract available.
-
The hamster cheek pouch carcinogenesis model.Acta Odontol Latinoam. 1993;7(1):3-12. Acta Odontol Latinoam. 1993. PMID: 11885256 Review. No abstract available.
Cited by
-
In vivo validation of a bimodal technique combining time-resolved fluorescence spectroscopy and ultrasonic backscatter microscopy for diagnosis of oral carcinoma.J Biomed Opt. 2012 Nov;17(11):116003. doi: 10.1117/1.JBO.17.11.116003. J Biomed Opt. 2012. PMID: 23117798 Free PMC article.
-
New frontier in hypericin-mediated diagnosis of cancer with current optical technologies.Ann Biomed Eng. 2012 Feb;40(2):460-73. doi: 10.1007/s10439-011-0462-7. Epub 2011 Nov 29. Ann Biomed Eng. 2012. PMID: 22124793 Free PMC article. Review.
-
In vivo diagnosis of oral dysplasia and malignancy using optical coherence tomography: preliminary studies in 50 patients.Lasers Surg Med. 2009 Jul;41(5):353-7. doi: 10.1002/lsm.20773. Lasers Surg Med. 2009. PMID: 19533765 Free PMC article.
-
Thin polymer etalon arrays for high-resolution photoacoustic imaging.J Biomed Opt. 2008 Nov-Dec;13(6):064033. doi: 10.1117/1.3042260. J Biomed Opt. 2008. PMID: 19123679 Free PMC article.
-
Automated analysis of multimodal fluorescence lifetime imaging and optical coherence tomography data for the diagnosis of oral cancer in the hamster cheek pouch model.Biomed Opt Express. 2016 Apr 25;7(5):2000-15. doi: 10.1364/BOE.7.002000. eCollection 2016 May 1. Biomed Opt Express. 2016. PMID: 27231638 Free PMC article.