Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Sep;91(9):1174-82.
doi: 10.1002/bjs.4430.

Development of a dedicated risk-adjustment scoring system for colorectal surgery (colorectal POSSUM)

Affiliations

Development of a dedicated risk-adjustment scoring system for colorectal surgery (colorectal POSSUM)

P P Tekkis et al. Br J Surg. 2004 Sep.

Abstract

Background: The aim of the study was to develop a dedicated colorectal Physiological and Operative Severity Score for the enUmeration of Mortality and morbidity (CR-POSSUM) equation for predicting operative mortality, and to compare its performance with the Portsmouth (P)-POSSUM model.

Methods: Data were collected prospectively from 6883 patients undergoing colorectal surgery in 15 UK hospitals between 1993 and 2001. After excluding missing data and 93 patients who did not satisfy the inclusion criteria, 4632 patients (68.2 per cent) underwent elective surgery and 2107 had an emergency operation (31.0 per cent); 2437 operations (35.9 per cent) for malignant and 4267 (62.8 per cent) for non-malignant diseases were scored. Stepwise logistic regression analysis was used to develop an age-adjusted POSSUM model and a dedicated CR-POSSUM model. A 60:40 per cent split-sample validation technique was adopted for model development and testing. Observed and expected mortality rates were compared.

Results: The operative mortality rate for the series was 5.7 per cent (387 of 6790 patients) (elective operations 2.8 per cent; emergency surgery 12.0 per cent). The CR-POSSUM, age-adjusted POSSUM and P-POSSUM models had similar areas under the receiver-operator characteristic curves. Model calibration was similar for CR-POSSUM and age-adjusted POSSUM models, and superior to that for the P-POSSUM model. The CR-POSSUM model offered the best overall accuracy, with an observed : expected ratio of 1.000, 0.998 and 0.911 respectively (test population).

Conclusion: The CR-POSSUM model provided an accurate predictor of operative mortality. External validation is required in hospitals different from those in which the model was developed.

PubMed Disclaimer

Publication types