Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1992 Mar 15;19(4):780-8.
doi: 10.1016/0735-1097(92)90518-r.

Long-term outcome of survivors of cardiac arrest whose therapy is guided by electrophysiologic testing

Affiliations
Free article
Comparative Study

Long-term outcome of survivors of cardiac arrest whose therapy is guided by electrophysiologic testing

R N Fogoros et al. J Am Coll Cardiol. .
Free article

Abstract

The long-term outcome of 217 consecutive survivors of cardiac arrest whose therapy was guided by electrophysiologic testing was analyzed. After electrophysiologic testing, 81 patients (37%) were classified as having no inducible arrhythmia and were treated without antiarrhythmic drugs; 23 received an implantable defibrillator. Of the 136 patients with inducible arrhythmia, the 51 (38%) who responded to serial drug testing were treated with the successful drug and the 85 (62%) with unsuccessful drug testing were treated with an implantable defibrillator (47 patients), amiodarone (36 patients) or drugs that were unsuccessful during testing (2 patients). The mean follow-up interval for all patients was 35 +/- 23 months. The actuarial incidence of sudden death and overall death was similar for patients whose arrhythmias were not inducible, drug responders and nonresponders. The actuarial incidence rate of recurrent arrhythmic events in nonresponders was 35 +/- 5% and 53 +/- 7% at 2 and 5 years, respectively. These values were significantly lower (and statistically similar to each other) in the other two patient groups: patients with noninducible arrhythmia (19 +/- 5% and 31 +/- 7%, respectively, p less than 0.05) and drug responders (13 +/- 5% and 23 +/- 8%, respectively, p less than 0.01). Patients with an implantable defibrillator who had recurrent arrhythmic events were significantly less likely to die suddenly than were patients without a defibrillator who had recurrent events (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)