Microvolt T-wave alternans distinguishes between patients likely and patients not likely to benefit from implanted cardiac defibrillator therapy: a solution to the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II conundrum
- PMID: 15451804
- DOI: 10.1161/01.CIR.0000143160.14610.53
Microvolt T-wave alternans distinguishes between patients likely and patients not likely to benefit from implanted cardiac defibrillator therapy: a solution to the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II conundrum
Abstract
Background: In 2003, the Centers for Medicaid and Medicare Services recommended QRS duration as a means to identify MADIT II-like patients suitable for implanted cardiac defibrillator (ICD) therapy. We compared the ability of microvolt T-wave alternans and QRS duration to identify groups at high and low risk of dying among heart failure patients who met MADIT II criteria for ICD prophylaxis.
Methods and results: Patients with MADIT II characteristics and sinus rhythm had a microvolt T-wave alternans exercise test and a 12-lead ECG. Our primary end point was 2-year all-cause mortality. Of 177 MADIT II-like patients, 32% had a QRS duration >120 ms, and 68% had an abnormal (positive or indeterminate) microvolt T-wave alternans test. During an average follow-up of 20+/-6 months, 20 patients died. We compared patients with an abnormal microvolt T-wave alternans test to those with a normal (negative) test, and patients with a QRS >120 ms with those with a QRS < or =120 ms; the hazard ratios for 2-year mortality were 4.8 (P=0.020) and 1.5 (P=0.367), respectively. The actuarial mortality rate was substantially lower among patients with a normal microvolt T-wave alternans test (3.8%; 95% confidence interval: 0, 9.0) than the mortality rate in patients with a narrow QRS (12.0%; 95% confidence interval: 5.6, 18.5). The corresponding false-negative rates are 3.5% and 10.2%, respectively.
Conclusions: Among MADIT II-like patients, a microvolt T-wave alternans test is better than QRS duration at identifying a high-risk group and also better at identifying a low-risk group unlikely to benefit from ICD therapy.
Comment in
-
Letters regarding article by Bloomfield et al, "microvolt T-wave alternans distinguishes between patients likely and patients not likely to benefit from implanted cardiac defibrillator therapy".Circulation. 2005 May 17;111(19):e299-300; author reply e299-300. doi: 10.1161/01.CIR.0000165124.18526.25. Circulation. 2005. PMID: 15897353 No abstract available.
-
Letters regarding article by Bloomfield et al, "microvolt T-wave alternans distinguishes between patients likely and patients not likely to benefit from implanted cardiac defibrillator therapy".Circulation. 2005 May 17;111(19):e299-300; author reply e299-300. Circulation. 2005. PMID: 15900622 No abstract available.
Similar articles
-
Cost-effectiveness of a microvolt T-wave alternans screening strategy for implantable cardioverter-defibrillator placement in the MADIT-II-eligible population.J Am Coll Cardiol. 2006 Jul 4;48(1):112-21. doi: 10.1016/j.jacc.2006.02.051. Epub 2006 Jun 9. J Am Coll Cardiol. 2006. PMID: 16814657
-
Prognostic value of T-wave alternans in patients with heart failure due to nonischemic cardiomyopathy: results of the ALPHA Study.J Am Coll Cardiol. 2007 Nov 6;50(19):1896-904. doi: 10.1016/j.jacc.2007.09.004. Epub 2007 Oct 22. J Am Coll Cardiol. 2007. PMID: 17980258
-
Does microvolt T-wave alternans testing predict ventricular tachyarrhythmias in patients with ischemic cardiomyopathy and prophylactic defibrillators? The MASTER (Microvolt T Wave Alternans Testing for Risk Stratification of Post-Myocardial Infarction Patients) trial.J Am Coll Cardiol. 2008 Nov 11;52(20):1607-15. doi: 10.1016/j.jacc.2008.08.018. J Am Coll Cardiol. 2008. PMID: 18992649
-
Enhancing specificity without sacrificing sensitivity: potential benefits of using microvolt T-wave alternans testing to risk stratify the MADIT-II population.Card Electrophysiol Rev. 2003 Dec;7(4):438-42. doi: 10.1023/B:CEPR.0000023161.35685.68. Card Electrophysiol Rev. 2003. PMID: 15071271 Review.
-
Can microvolt T-wave alternans testing reduce unnecessary defibrillator implantation?Nat Clin Pract Cardiovasc Med. 2005 Oct;2(10):522-8. doi: 10.1038/ncpcardio0323. Nat Clin Pract Cardiovasc Med. 2005. PMID: 16186850 Review.
Cited by
-
Microvolt-level T-wave alternans determination using the spectral method in patients with QT prolongation: value of adjusting the T-wave window.J Electrocardiol. 2012 Nov-Dec;45(6):758-63. doi: 10.1016/j.jelectrocard.2012.07.007. Epub 2012 Sep 7. J Electrocardiol. 2012. PMID: 22960166 Free PMC article.
-
SCD in patients with cardiomyopathy: use of microvolt T-wave alternans and other noninvasive tests for risk stratification and prevention of SCD.Curr Treat Options Cardiovasc Med. 2007 Oct;9(5):345-55. doi: 10.1007/s11936-007-0054-x. Curr Treat Options Cardiovasc Med. 2007. PMID: 17897563
-
Non-invasive evaluation of arrhythmic risk in dilated cardiomyopathy: From imaging to electrocardiographic measures.World J Cardiol. 2014 Jul 26;6(7):562-76. doi: 10.4330/wjc.v6.i7.562. World J Cardiol. 2014. PMID: 25068017 Free PMC article. Review.
-
Risk of arrhythmic death in ischemic heart disease: a prospective, controlled, observer-blind risk stratification over 10 years.Eur J Clin Invest. 2017 Mar;47(3):231-240. doi: 10.1111/eci.12729. Epub 2017 Feb 11. Eur J Clin Invest. 2017. PMID: 28102901 Free PMC article.
-
Electrocardiographic predictors of arrhythmic death.Ann Noninvasive Electrocardiol. 2006 Oct;11(4):327-37. doi: 10.1111/j.1542-474X.2006.00125.x. Ann Noninvasive Electrocardiol. 2006. PMID: 17040281 Free PMC article. Review. No abstract available.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous