Depth-resolved birefringence and differential optical axis orientation measurements with fiber-based polarization-sensitive optical coherence tomography
- PMID: 15455768
- DOI: 10.1364/ol.29.002025
Depth-resolved birefringence and differential optical axis orientation measurements with fiber-based polarization-sensitive optical coherence tomography
Abstract
Conventional polarization-sensitive optical coherence tomography (PS-OCT) can provide depth-resolved Stokes parameter measurements of light reflected from turbid media. A new algorithm that takes into account changes in the optical axis is introduced to provide depth-resolved birefringence and differential optical axis orientation images by use of fiber-based PS-OCT. Quaternion, a convenient mathematical tool, is used to represent an optical element and simplify the algorithm. Experimental results with beef tendon and rabbit tendon and muscle show that this technique has promising potential for imaging the birefringent structure of multiple-layer samples with varying optical axes.
Similar articles
-
Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components.Opt Lett. 2004 Nov 1;29(21):2512-4. doi: 10.1364/ol.29.002512. Opt Lett. 2004. PMID: 15584278 Free PMC article.
-
En face parametric imaging of tissue birefringence using polarization-sensitive optical coherence tomography.J Biomed Opt. 2013 Jun;18(6):066005. doi: 10.1117/1.JBO.18.6.066005. J Biomed Opt. 2013. PMID: 23733021
-
Variables affecting polarization-sensitive optical coherence tomography imaging examined through the modeling of birefringent phantoms.J Opt Soc Am A Opt Image Sci Vis. 2005 Feb;22(2):262-71. doi: 10.1364/josaa.22.000262. J Opt Soc Am A Opt Image Sci Vis. 2005. PMID: 15717555
-
Review of polarization sensitive optical coherence tomography and Stokes vector determination.J Biomed Opt. 2002 Jul;7(3):359-71. doi: 10.1117/1.1483879. J Biomed Opt. 2002. PMID: 12175285 Review.
-
Polarization-resolved Stokes-Mueller imaging: a review of technology and applications.Lasers Med Sci. 2019 Sep;34(7):1283-1293. doi: 10.1007/s10103-019-02752-1. Epub 2019 Mar 4. Lasers Med Sci. 2019. PMID: 30830559 Review.
Cited by
-
Polarization-sensitive optical coherence elastography.Biomed Opt Express. 2019 Sep 16;10(10):5162-5181. doi: 10.1364/BOE.10.005162. eCollection 2019 Oct 1. Biomed Opt Express. 2019. PMID: 31646039 Free PMC article.
-
Label-free functional and structural imaging of liver microvascular complex in mice by Jones matrix optical coherence tomography.Sci Rep. 2021 Oct 8;11(1):20054. doi: 10.1038/s41598-021-98909-6. Sci Rep. 2021. PMID: 34625574 Free PMC article.
-
High-fidelity approximation of grid- and shell-based sampling schemes from undersampled DSI using compressed sensing: Post mortem validation.Neuroimage. 2021 Dec 1;244:118621. doi: 10.1016/j.neuroimage.2021.118621. Epub 2021 Sep 26. Neuroimage. 2021. PMID: 34587516 Free PMC article.
-
Optic axis mapping with catheter-based polarization-sensitive optical coherence tomography.Optica. 2018 Oct 20;5(10):1329-1337. doi: 10.1364/OPTICA.5.001329. Optica. 2018. PMID: 31214632 Free PMC article.
-
Swept source/Fourier domain polarization sensitive optical coherence tomography with a passive polarization delay unit.Opt Express. 2012 Apr 23;20(9):10229-41. doi: 10.1364/OE.20.010229. Opt Express. 2012. PMID: 22535114 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources