Errors in body temperature measurement might seriously influence the evaluation of an individual's health condition. We studied individual variation, measurement technique and the equipment used when assessing body temperature. In the first part of the study, three volunteers performed repeated measurements for five mornings. In the second part, the morning rectal, oral, ear and axillary temperatures were measured once in 84 men and women (19-59 years). The repeated measurements showed a daily temperature difference of 0.1-0.4 degrees C in rectal and oral temperatures, 0.2 degrees C-1.7 degrees C in the ear and 0.1-0.9 degrees C in the axillary temperatures. In the sample of 84 subjects, men and postmenopausal women had a lower mean body temperature compared to premenopausal women. The mean deviation between rectal temperature, and oral, ear and axillary temperatures, respectively, was > 0.5 degrees C, with a large individual variation. In conclusion, in order to improve the evaluation of body temperature, the assessment should be based on the individual variation, the same site of measurement and no adjustment of oral, ear or axillary temperatures to the rectal site.
Similar articles
-
Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people.J Clin Nurs. 2005 Apr;14(4):496-500. doi: 10.1111/j.1365-2702.2004.01076.x. J Clin Nurs. 2005. PMID: 15807757
-
Accuracy of infrared ear thermometry and traditional temperature methods in young children.Heart Lung. 1994 May-Jun;23(3):181-95. Heart Lung. 1994. PMID: 8039988 Clinical Trial.
-
Reliability of body temperature measurements in hospitalised older patients.J Clin Nurs. 2008 Jun;17(11):1518-25. doi: 10.1111/j.1365-2702.2007.02140.x. J Clin Nurs. 2008. PMID: 18482145
-
Accuracy of noninvasive core temperature measurement in acutely ill adults: the state of the science.Biol Res Nurs. 2006 Jul;8(1):24-34. doi: 10.1177/1099800406289151. Biol Res Nurs. 2006. PMID: 16766626 Review.
-
Thermoregulation and axillary temperature measurements in neonates: a review of the literature.Matern Child Nurs J. 1992 Fall-Winter;20(3-4):124-40. Matern Child Nurs J. 1992. PMID: 1301477 Review.
Cited by
-
The Effect of Remimazolam Compared to Sevoflurane on Postoperative Shivering in Patients Undergoing Laparoscopic Gynecologic Surgery under General Anesthesia: A Prospective Randomized Controlled Trial.Medicina (Kaunas). 2023 Mar 15;59(3):578. doi: 10.3390/medicina59030578. Medicina (Kaunas). 2023. PMID: 36984579 Free PMC article. Clinical Trial.
-
Investigation of Non-invasive Continuous Body Temperature Measurements in a Clinical Setting Using an Adhesive Axillary Thermometer (SteadyTemp®).Front Digit Health. 2021 Dec 14;3:794274. doi: 10.3389/fdgth.2021.794274. eCollection 2021. Front Digit Health. 2021. PMID: 34970650 Free PMC article.
-
Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites.Sensors (Basel). 2020 May 19;20(10):2885. doi: 10.3390/s20102885. Sensors (Basel). 2020. PMID: 32438729 Free PMC article.
-
Thermography and thermoregulation of the face.Head Face Med. 2007 Mar 15;3:17. doi: 10.1186/1746-160X-3-17. Head Face Med. 2007. PMID: 17362518 Free PMC article.
-
The value of fever assessment in addition to the Early Detection Infection Scale (EDIS). A validation study in nursing home residents in Sweden.BMC Geriatr. 2023 Sep 22;23(1):585. doi: 10.1186/s12877-023-04266-6. BMC Geriatr. 2023. PMID: 37737163 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical