Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Oct 6;44(7):1467-72.
doi: 10.1016/j.jacc.2003.12.060.

Prevalence and severity of paravalvular regurgitation in the Artificial Valve Endocarditis Reduction Trial (AVERT) echocardiography study

Affiliations
Free article
Clinical Trial

Prevalence and severity of paravalvular regurgitation in the Artificial Valve Endocarditis Reduction Trial (AVERT) echocardiography study

Victor G Dávila-Román et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: The purpose of this study was to determine the prevalence and severity of paravalvular regurgitation (PVR) in the Artificial Valve Endocarditis Reduction Trial (AVERT) cohort.

Background: The initial AVERT cohort consisted of 807 patients randomized to receive either a Silzone-coated prosthetic valve or a conventional prosthetic valve; early clinical reports showed higher rates of valve explant caused by PVR for Silzone-coated prosthetic valve.

Methods: Of the 678 eligible patients, 575 (85%) underwent postoperative transthoracic echocardiograms. The presence and severity of PVR were identified by color flow Doppler. Reviewers were blinded to the type of prosthetic valve and the demographic and clinical variables.

Results: Among those who underwent echocardiography (Silzone-coated prosthetic valve, n = 285 and conventional prosthetic valve, n = 290), 59% had prosthetic aortic valves, 32% prosthetic mitral valves, and 9% had both; demographic and clinical findings (i.e., prosthetic valve endocarditis, thromboembolism, bleeding, and all-cause death) were similar for the two groups. Echocardiographically determined PVR was present in 50 valves: Silzone-coated prosthetic valve, 29 of 285 (10%) and conventional prosthetic valve, 21 of 290 (7%, p = NS); the severity of PVR was similar in both groups. Kaplan-Meier analysis showed no significant differences in PVR at 24 months from valve implantation between the two groups (24-month event-free rate: 93% Silzone-coated prosthetic valve vs. 94% conventional prosthetic valve, p = NS).

Conclusions: Excluding those patients who had initial prosthetic valve explant, the two-year echocardiographic follow-up of the AVERT cohort shows no statistically significant differences in the prevalence or severity of PVR in the Silzone-coated prosthetic valve compared with the conventional prosthetic valve. Further monitoring is warranted to determine whether these clinical outcomes remain similar on long-term follow-up.

PubMed Disclaimer

Publication types

MeSH terms