Detection of bioavailable heavy metals in EILATox-Oregon samples using whole-cell luminescent bacterial sensors in suspension or immobilized onto fibre-optic tips
- PMID: 15478176
- DOI: 10.1002/jat.1020
Detection of bioavailable heavy metals in EILATox-Oregon samples using whole-cell luminescent bacterial sensors in suspension or immobilized onto fibre-optic tips
Abstract
At the EILATox-Oregon Workshop, nine luminescent whole-cell bacterial sensors were used for the determination of bioavailable metals in blind samples (17 synthetic and 3 environmental). A non-inducible luminescent control strain was used to determine sample matrix effects and bacterial toxicity. Whole-cell bacterial sensors capable of determining arsenic, inorganic mercury and its organic derivatives, cadmium, lead or copper were used in suspensions and a bacterial sensor for the detection of inorganic mercury was immobilized onto fibre-optic tips using calcium alginate. Bioavailable amounts of metals were estimated using calibration plots, that were constructed to determine the range of metals giving rise to a linear relationship between luminescence and the amount of metals present in the standard solutions. EILATox-Oregon sample 5, which contained 74 mg l(-1) of Hg, gave a significant response with both formats of the mercury sensor. The bioavailable amounts of mercury according to the measurement of bacterial sensor in suspension and immobilized onto a fibre-optic tip were 76 and 93 mg l(-1), respectively. The bacterial sensor for arsenic and copper showed a response with sample 6 (58 mg l(-1) of As) and sample 8 (400 mg l(-1) of metham sodium), respectively. This study showed that the bacterial sensors in suspension or immobilized onto optical fibres are capable of quantifying bioavailable metals from unknown samples. The measurement protocol of bacterial sensors is simple and possible to perform in the field. Moreover, the samples do not need any pretreatment before analysis. Construction and characterization of the strain for the detection of bioavailable copper are described.
Copyright (c) 2004 John Wiley & Sons, Ltd.
Similar articles
-
Fibre-optic bacterial biosensors and their application for the analysis of bioavailable Hg and As in soils and sediments from Aznalcollar mining area in Spain.Biosens Bioelectron. 2007 Feb 15;22(7):1396-402. doi: 10.1016/j.bios.2006.06.019. Epub 2006 Aug 4. Biosens Bioelectron. 2007. PMID: 16889954
-
Toxicity detection from EILATox-Oregon Workshop samples by using kinetic photobacteria measurement: the Flash method.J Appl Toxicol. 2004 Sep-Oct;24(5):349-53. doi: 10.1002/jat.1021. J Appl Toxicol. 2004. PMID: 15478213
-
Recombinant luminescent bacterial sensors for the measurement of bioavailability of cadmium and lead in soils polluted by metal smelters.Chemosphere. 2004 Apr;55(2):147-56. doi: 10.1016/j.chemosphere.2003.10.064. Chemosphere. 2004. PMID: 14761687
-
Genetically encoded fluorescent sensors for measuring transition and heavy metals in biological systems.Curr Opin Chem Biol. 2018 Apr;43:87-96. doi: 10.1016/j.cbpa.2017.12.002. Epub 2017 Dec 21. Curr Opin Chem Biol. 2018. PMID: 29275290 Review.
-
Modified electrodes used for electrochemical detection of metal ions in environmental analysis.Biosensors (Basel). 2015 Apr 29;5(2):241-75. doi: 10.3390/bios5020241. Biosensors (Basel). 2015. PMID: 25938789 Free PMC article. Review.
Cited by
-
Microbial reporters of metal bioavailability.Microb Biotechnol. 2008 Jul;1(4):320-30. doi: 10.1111/j.1751-7915.2008.00022.x. Microb Biotechnol. 2008. PMID: 21261850 Free PMC article. Review.
-
Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors.Sensors (Basel). 2015 Sep 30;15(10):25208-59. doi: 10.3390/s151025208. Sensors (Basel). 2015. PMID: 26437407 Free PMC article. Review.
-
Identification of a copper-responsive promoter and development of a copper biosensor in the soil bacterium Achromobacter sp. AO22.World J Microbiol Biotechnol. 2012 May;28(5):2221-8. doi: 10.1007/s11274-012-1029-y. Epub 2012 Mar 6. World J Microbiol Biotechnol. 2012. PMID: 22806045
-
Dissolution of silver nanowires and nanospheres dictates their toxicity to Escherichia coli.Biomed Res Int. 2013;2013:819252. doi: 10.1155/2013/819252. Epub 2013 Aug 20. Biomed Res Int. 2013. PMID: 24024212 Free PMC article.
-
Reporter proteins in whole-cell optical bioreporter detection systems, biosensor integrations, and biosensing applications.Sensors (Basel). 2009;9(11):9147-74. doi: 10.3390/s91109147. Epub 2009 Nov 17. Sensors (Basel). 2009. PMID: 22291559 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials