Toxicity detection from EILATox-Oregon Workshop samples by using kinetic photobacteria measurement: the Flash method
- PMID: 15478213
- DOI: 10.1002/jat.1021
Toxicity detection from EILATox-Oregon Workshop samples by using kinetic photobacteria measurement: the Flash method
Abstract
The Flash test, which can be used to measure the toxicity from clear, turbid and coloured samples with identical protocol, was used in the EILATox-Oregon Workshop. During the workshop, 17 synthetic samples and three environmental samples were tested. In the Flash method the photobacteria Vibrio fischeri are initially dispensed on top of the sample and the light output of the bioluminescence reaction is recorded at a rate of several readings per second. The change in the light production was measured at two points: 30 s and 30 min after exposure at room temperature. Toxicity calculations were done by using either the peak height of the sample or the peak height of the control sample (maximum signal at 0-2 s). When the peak height of the sample is used as a reference, the colour and turbidity effect of solid particles are taken into account throughout the whole measurement period. In the EILATox-Oregon Workshop toxicity was seen in samples 1 (chlordimeform), 4 (phosdrin), 5 (HgCl(2)), 6 (sodium arsenite), 8 (metham sodium), 12 (p-chlorophenol), 14 (sodium selenite) and 17 (MNNG). Only samples 1, 4 and 12 showed different ec(50) values between different calculations of toxicity. The ec(50) values were calculated and compared with the ec(50) values of Microtox derived from the literature. The Flash test will not replace the standardized photobacteria test, but is the advanced version of it and is needed when the sample matrix is complex and when speed and low costs are required.
Copyright (c) 2004 John Wiley & Sons, Ltd.
Similar articles
-
EILATox-Oregon Workshop: blind study evaluation of Vitotox test with genotoxic and cytotoxic sample library.J Appl Toxicol. 2004 Sep-Oct;24(5):327-32. doi: 10.1002/jat.1019. J Appl Toxicol. 2004. PMID: 15478175
-
Water toxicity detection by a panel of stress-responsive luminescent bacteria.J Appl Toxicol. 2004 Sep-Oct;24(5):343-8. doi: 10.1002/jat.1023. J Appl Toxicol. 2004. PMID: 15478173
-
Detection of bioavailable heavy metals in EILATox-Oregon samples using whole-cell luminescent bacterial sensors in suspension or immobilized onto fibre-optic tips.J Appl Toxicol. 2004 Sep-Oct;24(5):333-42. doi: 10.1002/jat.1020. J Appl Toxicol. 2004. PMID: 15478176
-
A review on advantages of implementing luminescence inhibition test (Vibrio fischeri) for acute toxicity prediction of chemicals.Environ Int. 2006 Feb;32(2):265-8. doi: 10.1016/j.envint.2005.08.022. Epub 2005 Sep 26. Environ Int. 2006. PMID: 16188318 Review.
-
Water analysis: emerging contaminants and current issues.Anal Chem. 2007 Jun 15;79(12):4295-323. doi: 10.1021/ac070719q. Epub 2007 May 18. Anal Chem. 2007. PMID: 17508722 Review. No abstract available.