[Transmission of force to the trabecular structures of the proximal end of the femur]
- PMID: 1549338
[Transmission of force to the trabecular structures of the proximal end of the femur]
Abstract
Normal use places stress on the femur from different directions and with variable intensity. All these forces are introduced as pressure forces through the cartilage in a trajectory framing cancellous structure whose elements are primarily charged axially with tension and pressure. The effects of these forces on these structures were analyzed with different methods. Often we only looked for single aspects of the introduction the of force or worked with experimentally acquire approximations. To analyze the conditions for an authentic femur, we examined the trabecular structures of a proximal femur with computed tomography. We had some indications that the trabecular structures are not built linearly, as shown by von Meyer, Wolff, Goss and Singh. In our study we found a significant deviation of the epiphyseal trabeculae from the metaphyseal alignment. This makes us believe that even later the area of the former epiphysis plays a certain role in the distribution of supporting structures beneath the charged surface meaning to adapt to the effective stress.
Similar articles
-
Morphological analysis of the proximal femur using quantitative computed tomography.Int Orthop. 2007 Jun;31(3):287-92. doi: 10.1007/s00264-006-0182-z. Epub 2006 Aug 2. Int Orthop. 2007. PMID: 16896872 Free PMC article.
-
Function-orientated structural analysis of the proximal human femur.Cells Tissues Organs. 2009;190(5):247-55. doi: 10.1159/000210065. Epub 2009 Mar 25. Cells Tissues Organs. 2009. PMID: 19321950
-
Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions.J Biomech. 1999 Apr;32(4):443-51. doi: 10.1016/s0021-9290(99)00024-x. J Biomech. 1999. PMID: 10213036
-
[The clinical relevance of biomechanical analysis of the hip area].Z Orthop Ihre Grenzgeb. 1991 Jul-Aug;129(4):285-94. doi: 10.1055/s-2008-1040243. Z Orthop Ihre Grenzgeb. 1991. PMID: 1833916 Review. German.
-
[Stress on the coxal end of the femur during loading in the hip joint flexion posture].Aktuelle Probl Chir Orthop. 1990;39:1-56. Aktuelle Probl Chir Orthop. 1990. PMID: 1979902 Review. German. No abstract available.
Cited by
-
Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty.Int Orthop. 2007 Aug;31 Suppl 1(Suppl 1):S29-33. doi: 10.1007/s00264-007-0429-3. Int Orthop. 2007. PMID: 17661036 Free PMC article. Review.