Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2004 Oct-Nov;32(7):1668-74.
doi: 10.1177/0363546504266480.

Diagnostic accuracy of clinical assessment, magnetic resonance imaging, magnetic resonance arthrography, and intra-articular injection in hip arthroscopy patients

Affiliations

Diagnostic accuracy of clinical assessment, magnetic resonance imaging, magnetic resonance arthrography, and intra-articular injection in hip arthroscopy patients

J W Thomas Byrd et al. Am J Sports Med. 2004 Oct-Nov.

Abstract

Background: Hip arthroscopy has defined elusive causes of hip pain.

Hypothesis/purpose: It is postulated that the reliability of various investigative methods is inconsistent. The purpose of this study is to evaluate the diagnostic accuracy of these methods.

Study design: Retrospective review of prospectively collected data.

Methods: Five parameters were assessed in 40 patients: clinical assessment, high-resolution magnetic resonance imaging, magnetic resonance imaging with gadolinium arthrography, intra-articular bupivacaine injection, and arthroscopy. Using arthroscopy as the definitive diagnosis, the other parameters were evaluated for reliability.

Results: Hip abnormality was clinically suspected in all cases with 98% accuracy (1 false positive). However, the nature of the abnormality was identified in only 13 cases with 92% accuracy. Magnetic resonance imaging variously demonstrated direct or indirect evidence of abnormality but overall demonstrated a 42% false-negative and a 10% false-positive interpretation. Magnetic resonance arthrography demonstrated an 8% false-negative and 20% false-positive interpretation. Response to the intra-articular injection of anesthetic was 90% accurate (3 false-negative and 1 false-positive responses) for detecting the presence of intra-articular abnormality.

Conclusions: In this series, clinical assessment accurately determined the existence of intra-articular abnormality but was poor at defining its nature. Magnetic resonance arthrography was much more sensitive than magnetic resonance imaging at detecting various lesions but had twice as many false-positive interpretations. Response to an intra-articular injection of anesthetic was a 90% reliable indicator of intra-articular abnormality.

PubMed Disclaimer

Publication types