. 2005 Mar;288(3):H1491-7.
doi: 10.1152/ajpheart.00632.2004. Epub 2004 Oct 28.

Measurement of myocardial mechanics in mice before and after infarction using multislice displacement-encoded MRI with 3D motion encoding

Affiliations
Free article

Measurement of myocardial mechanics in mice before and after infarction using multislice displacement-encoded MRI with 3D motion encoding

Wesley D Gilson et al. Am J Physiol Heart Circ Physiol. 2005 Mar.
Free article

Abstract

Cardiac MRI is an accurate, noninvasive modality for assessing the structure and function of the murine heart. In addition to conventional imaging, MRI tissue tracking methods can quantify numerous aspects of myocardial mechanics, including intramyocardial displacement, strain, twist, and torsion. In the present study, we developed and applied a novel pulse sequence based on displacement-encoded imaging using stimulated echoes (DENSE) that achieves multislice coverage, high spatial resolution, and three-dimensional (3D) displacement encoding. With the use of this technique, myocardial mechanics of C57Bl/6 mice were measured at baseline and 1 day after experimental myocardial infarction. At baseline, the mean systolic transmural circumferential strain was -0.14 +/- 0.02 and the mean systolic radial strain was 0.30 +/- 0.05. Changes in circumferential and radial strains from the subepicardium to the subendocardium were detected at baseline (P < 0.05). One day after infarction, significantly reduced 3D displacements and strain were detected in infarcted and noninfarcted myocardium. Infarction also reduced normalized systolic torsion from its baseline value of 1.35 +/- 0.27 degrees /mm (R = 0.99) to 0.07 +/- 0.54 degrees /mm (R = 0.96, P < 0.05). DENSE MRI can assess the 3D myocardial mechanics of the murine heart in <1 h of scan time at 4.7 T and may be applied to studies of myocardial mechanics in genetically engineered mice.