A time-dependent healing function for immediate loaded implants
Abstract
Current interest in immediate dental implant loading has grown due to a number of clinical advantages this treatment modality offers. To obtain a deeper insight into the changing mechanical properties during the healing phase, results from removal torque tests are used in a biomechanical model. The ultimate removal torques, which depend on healing time, are described by a time-dependent healing function. The bone behavior is modeled using an elastic law with damage. The evolution of damage is represented with an incremental equation with an initial damage value and two material parameters. The nonlinear relationship between the torque and the angle of rotation up to the ultimate torque can be calculated. By changing the elastic parameter in the elastic damage law, the remodeling process can be characterized. In a further step, the elastic parameters and the limits for shear stress from the biomechanical model for the removal torque will be used in an FE analysis in order to obtain information on the axial loading limits of a dental implant at different healing times.
Similar articles
-
Numeric simulation of time-dependent remodeling of bone around loaded oral implants.Int J Oral Maxillofac Implants. 2009 Jul-Aug;24(4):597-608. Int J Oral Maxillofac Implants. 2009. PMID: 19885399
-
The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs.J Biomech Eng. 2007 Feb;129(1):12-9. doi: 10.1115/1.2401178. J Biomech Eng. 2007. PMID: 17227093
-
The dynamic natures of implant loading.J Prosthet Dent. 2009 Jun;101(6):359-71. doi: 10.1016/S0022-3913(09)60079-2. J Prosthet Dent. 2009. PMID: 19463663
-
Mechanical properties of implantable biomaterials.Clin Podiatr Med Surg. 1995 Jul;12(3):363-84. Clin Podiatr Med Surg. 1995. PMID: 7553529 Review.
-
[Electrically enhanced damaged tissues healing. Part I: direct current in bone healing].Pol Merkur Lekarski. 1999 May;6(35):294-6. Pol Merkur Lekarski. 1999. PMID: 10437406 Review. Polish.
Cited by
-
Predicting Peri-implant Stresses Around Titanium and Zirconium Dental Implants-A Finite Element Analysis.J Indian Prosthodont Soc. 2013 Sep;13(3):196-204. doi: 10.1007/s13191-013-0257-7. Epub 2013 Mar 13. J Indian Prosthodont Soc. 2013. PMID: 24431734 Free PMC article.
-
Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.Med Biol Eng Comput. 2015 May;53(5):453-62. doi: 10.1007/s11517-015-1256-0. Epub 2015 Mar 1. Med Biol Eng Comput. 2015. PMID: 25725630
-
Biomechanical behaviours of the bone-implant interface: a review.J R Soc Interface. 2019 Jul 26;16(156):20190259. doi: 10.1098/rsif.2019.0259. Epub 2019 Jul 31. J R Soc Interface. 2019. PMID: 31362615 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources