Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Sep-Oct;20(5 Suppl):S711-3.
doi: 10.3928/1081-597X-20040903-16.

Advanced surface ablation for presbyopia using the Nidek EC-5000 laser

Affiliations
Clinical Trial

Advanced surface ablation for presbyopia using the Nidek EC-5000 laser

Roberto Cantú et al. J Refract Surg. 2004 Sep-Oct.

Abstract

Purpose: To present 1 to 6-month follow-up results of laser in situ keratomileusis (LASIK) using multizone presbyopic advanced surface ablation (PASA) with a peripheral near zone.

Methods: LASIK was performed on 28 eyes of 17 patients (10 men and 7 women; mean age 49.8 years with a range of 37 to 62 years). Eyes had primary or enhancement treatments with the Nidek EC-5000 excimer laser. Three techniques were used: 1) total transepithelial ablation, 2) surface ablation for far vision ametropia correction, and 3) concentric peripheral near zone presbyopia correction (technique developed by Dr. A. Telandro with a modified nomogram by Dr. R. Cantú for surface ablation). One surgeon (RC) performed all surgery.

Results: We present the preoperative and postoperative measurements for far and near uncorrected visual acuity, total high order aberrations, spherical aberration (Z-12), asphericity Q index, eccentricity corneal shape factor, and total coma and trefoil aberrations. Increases occurred in negative spherical aberration, negative asphericity index, and positive eccentricity corneal shape factor.

Conclusions: Advanced surface ablation for presbyopia with a concentric peripheral near zone is a promising approach for surgical correction of presbyopia and potentially could be used with any advanced surface ablation procedure. Increases in negative spherical aberration and asphericity/ eccentricity indices seemed to increase the depth of focus of the eye, improving the near vision.