Prediction of ductus arteriosus closure by neonatal screening echocardiography
- PMID: 15529905
- DOI: 10.1023/b:caim.0000041933.61896.55
Prediction of ductus arteriosus closure by neonatal screening echocardiography
Abstract
Aims: We reported the incidence, clinical manifestations and outcome of patent ductus arteriosus (PDA) in full-term infants by screening echocardiography.
Methods and results: Total 1230 infants received echocardiographic screening and periodic follow-up. On the third day of life, there were 109 infants with isolated ductus arteriosus aneurysm (DAA), those with persistent patency of the ductus arteriosus (DA) in 26. The DA closed within 48 h in 828 infants, and persisted beyond 48 h in 180. The incidence of PDA in full-term infants was 0.91, 0.83 and 0.66% at 1, 4 and 6 months follow-up, and 0.82, 0.73 and 0.64% if infants with DAA were excluded. Infants with PDA had lower birth body weight (BBW) than those with closed DA (p = 0.02). The DA width on the third day of life ranged from 0.23 to 0.43 cm (0.32+/-0.08 cm) and 0.08 to 0.44 cm (0.16+/-0.06 cm) in infants with or without PDA, respectively, which was significantly different (p < 0.05). The sensitivity, specificity, predictive positive and negative values were 87.5, 92.5, 36.8 and 99% respectively for the cuff-off point at 0.25 cm of DA width.
Conclusions: Risk factors in infants with PDA included lower BBW and larger measured DA width at the third day of life. We predicted the arterial duct would close if DA width <0.25 cm, and suggested follow up earlier if >0.25 cm on the third day of life.
Similar articles
-
Prediction of ductus arteriosus closure by neonatal screening echocardiography.Int J Cardiovasc Imaging. 2004 Oct;20(5):349-56. Int J Cardiovasc Imaging. 2004. PMID: 15765856
-
Natural evolution of patent ductus arteriosus in the extremely preterm infant.Arch Dis Child Fetal Neonatal Ed. 2015 Jan;100(1):F55-8. doi: 10.1136/archdischild-2014-306339. Epub 2014 Aug 28. Arch Dis Child Fetal Neonatal Ed. 2015. PMID: 25169243
-
Echocardiographic assessment of patent ductus arteriosus shunt flow pattern in premature infants.Arch Dis Child Fetal Neonatal Ed. 1997 Jul;77(1):F36-40. doi: 10.1136/fn.77.1.f36. Arch Dis Child Fetal Neonatal Ed. 1997. PMID: 9279181 Free PMC article.
-
Echocardiography for patent ductus arteriosus including closure in adults.Echocardiography. 2015 Jan;32 Suppl 2:S125-39. doi: 10.1111/echo.12457. Epub 2014 May 29. Echocardiography. 2015. PMID: 24888537 Review.
-
The ductus arteriosus: physiology, regulation, and functional and congenital anomalies.Arch Cardiovasc Dis. 2011 Nov;104(11):578-85. doi: 10.1016/j.acvd.2010.06.006. Epub 2010 Sep 21. Arch Cardiovasc Dis. 2011. PMID: 22117910 Review.
Cited by
-
Factors Predicting Spontaneous Closure of Patent Ductus Arteriosus in Very Low Birth Weight Neonates.Cureus. 2024 Aug 30;16(8):e68241. doi: 10.7759/cureus.68241. eCollection 2024 Aug. Cureus. 2024. PMID: 39347222 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical