Sensors for toxicity of chemicals and oxidative stress based on electrochemical catalytic DNA oxidation
- PMID: 15530799
- DOI: 10.1016/j.bios.2004.06.033
Sensors for toxicity of chemicals and oxidative stress based on electrochemical catalytic DNA oxidation
Abstract
Films of DNA, enzymes, polyions, and catalytic redox polyions of nanometer thickness on electrodes can provide active elements for sensors for screening the toxicity of chemicals and their metabolites, and for oxidative stress. The unifying feature of this approach involves layer-by-layer electrostatic assembly of films designed to detect DNA damage. Films containing DNA and enzymes enable detection of structural damage to DNA as a basis for toxicity screening. These films bioactivate chemicals to their metabolites, which can then react with DNA, mimicking toxicity pathways in the human liver. Metallopolyions that catalyze DNA oxidation can be incorporated into DNA/enzyme films leading to "reagentless" sensors. These sensors are suitable for detecting relative DNA damage rates in <5 min of the enzyme reactions. Films of the osmium polymer [Os(bpy)(2)(PVP)(10)Cl](+) [poly(vinylpyridine), PVP] can be used to monitor DNA oxidation selectively. Such films may be applicable to determination of oxidized DNA as a clinical biomarker for oxidative stress. Inclusion of the analogous ruthenium metallopolymer in the sensor provides a monitor for oxidation of other nucleobases.
Similar articles
-
Voltammetric sensor for oxidized DNA using ultrathin films of osmium and ruthenium metallopolymers.Anal Chem. 2004 Sep 15;76(18):5557-63. doi: 10.1021/ac049375j. Anal Chem. 2004. PMID: 15362921
-
Electrochemical DNA sensors.Nat Biotechnol. 2003 Oct;21(10):1192-9. doi: 10.1038/nbt873. Nat Biotechnol. 2003. PMID: 14520405 Review.
-
Use of polymeric indicator for electrochemical DNA sensors: poly(4-vinylpyridine) derivative bearing [Os(5,6-dimethyl-1,10-phenanthroline)2Cl]2+.Anal Chem. 2004 May 15;76(10):2975-80. doi: 10.1021/ac0303970. Anal Chem. 2004. PMID: 15144212
-
Using exonuclease III to enhance electrochemical detection of natural DNA damage in layered films.Biosens Bioelectron. 2008 Feb 28;23(7):1077-82. doi: 10.1016/j.bios.2007.10.019. Epub 2007 Nov 4. Biosens Bioelectron. 2008. PMID: 18055191
-
Cytochrome P450 biosensors-a review.Biosens Bioelectron. 2005 Jun 15;20(12):2408-23. doi: 10.1016/j.bios.2004.11.023. Epub 2005 Jan 5. Biosens Bioelectron. 2005. PMID: 15854816 Review.
Cited by
-
Screening reactive metabolites bioactivated by multiple enzyme pathways using a multiplexed microfluidic system.Analyst. 2013 Jan 7;138(1):171-8. doi: 10.1039/c2an35993f. Epub 2012 Oct 25. Analyst. 2013. PMID: 23095952 Free PMC article.
-
State-of-the-Art Metabolic Toxicity Screening and Pathway Evaluation.Anal Chem. 2016 May 3;88(9):4584-99. doi: 10.1021/acs.analchem.5b04772. Epub 2016 Apr 14. Anal Chem. 2016. PMID: 27043322 Free PMC article.
-
Electrochemically assisted fabrication of size-exclusion films of organically modified silica and application to the voltammetry of phospholipids.J Solid State Electrochem. 2013 Jun 1;17(6):1581-1590. doi: 10.1007/s10008-013-2077-4. J Solid State Electrochem. 2013. PMID: 23935394 Free PMC article.
-
Screening Genotoxicity Chemistry with Microfluidic Electrochemiluminescent Arrays.Sensors (Basel). 2017 May 3;17(5):1008. doi: 10.3390/s17051008. Sensors (Basel). 2017. PMID: 28467352 Free PMC article. Review.
-
Electrochemiluminescence Arrays for Studies of Metabolite-related Toxicity.Electroanalysis. 2016 Nov;28(11):2636-2643. doi: 10.1002/elan.201600207. Epub 2016 Jun 1. Electroanalysis. 2016. PMID: 28592918 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources