Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2004;42(6):877-88.
doi: 10.1081/clt-200035286.

A meta-analysis of prognostic indicators to predict seizures, arrhythmias or death after tricyclic antidepressant overdose

Affiliations
Meta-Analysis

A meta-analysis of prognostic indicators to predict seizures, arrhythmias or death after tricyclic antidepressant overdose

Benoit Bailey et al. J Toxicol Clin Toxicol. 2004.

Abstract

Objectives: To systematically review and summarize studies on the accuracy of ECG and tricyclic antidepressant (TCA) concentration as prognostic indicators of the risk of seizures, ventricular arrhythmia (VA) or death in patients with TCA overdose.

Methods: Articles were identified with MedLine and Cochrane register of controlled clinical trials searches and review of medical toxicology textbooks. Quality of the included studies was assessed. Pooled estimates of sensitivity, specificity, likelihood ratios and Summary Receiver Operating Characteristics (SROC) curves were generated.

Results: A total of 18 studies were included in the analysis. The pooled sensitivity (Se) and specificity (Sp) of the QRS for predicting seizures were 0.69 [95% CI 0.57-0.78] and 0.69 [95% CI 0.58-0.78] as compared to 0.75 [95% CI 0.61-0.85] and 0.72 [95% CI 0.61-0.81] for the TCA concentration. The Se and Sp of the QRS to predict VA were 0.79 [95% CI 0.58-0.91] and 0.46 [95% CI 0.35-0.59] compared to 0.78 [95% CI 0.56-0.90] and 0.57 [95% CI 0.46-0.67] for the TCA concentration. The Se and Sp of the QRS to predict death were 0.81 [95% CI 0.54-0.94] and 0.62 [95% CI 0.55-0.68] compared to 0.76 [95% CI 0.49-0.91] and 0.60 [95% CI 0.47-0.72] for the TCA concentration. Very few studies evaluated the accuracy of QTc, T 40 ms axis and the R/S ratio.

Conclusions: Overall, the studies suggested that the ECG and TCA concentration have similar but relatively poor performance for predicting complications, such as seizures, VA or death, associated with TCA overdose.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources