Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature
- PMID: 15534420
- DOI: 10.1097/01.brs.0000137069.88904.03
Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature
Abstract
Study design: Review of the literature.
Objectives: Review the definition, etiology, incidence, and risk factors associated with as well as potential treatment options.
Summary of background data: The development of pathology at the mobile segment next to a lumbar or lumbosacral spinal fusion has been termed adjacent segment disease. Initially reported to occur rarely, it is now considered a potential late complication of spinal fusion that can necessitate further surgical intervention and adversely affect outcomes.
Methods: MEDLINE literature search.
Results: The most common abnormal finding at the adjacent segment is disc degeneration. Biomechanical changes consisting of increased intradiscal pressure, increased facet loading, and increased mobility occur after fusion and have been implicated in causing adjacent segment disease. Progressive spinal degeneration with age is also thought to be a major contributor. From a radiographic standpoint, reported incidence during average postoperative follow-up observation ranging from 36 to 369 months varies substantially from 5.2 to 100%. Incidence of symptomatic adjacent segment disease is lower, however, ranging from 5.2 to 18.5% during 44.8 to 164 months of follow-up observation. The rate of symptomatic adjacent segment disease is higher in patients with transpedicular instrumentation (12.2-18.5%) compared with patients fused with other forms of instrumentation or with no instrumentation (5.2-5.6%). Potential risk factors include instrumentation, fusion length, sagittal malalignment, facet injury, age, and pre-existing degenerative changes.
Conclusion: Biomechanical alterations likely play a primary role in causing adjacent segment disease. Radiographically apparent, asymptomatic adjacent segment disease is common but does not correlate with functional outcomes. Potentially modifiable risk factors for the development of adjacent segment disease include fusion without instrumentation, protecting the facet joint of the adjacent segment during placement of pedicle screws,fusion length, and sagittal balance. Surgical management, when indicated, consists of decompression of neural elements and extension of fusion. Outcomes after surgery, however, are modest.
Similar articles
-
[Adjacent segment degeneration after lumbosacral fusion in spondylolisthesis: a retrospective radiological and clinical analysis].Acta Chir Orthop Traumatol Cech. 2010 Apr;77(2):124-30. Acta Chir Orthop Traumatol Cech. 2010. PMID: 20447355 Czech.
-
Segmental motion adjacent to an instrumented lumbar fusion: the effect of extension of fusion to the sacrum.Spine (Phila Pa 1976). 2004 Nov 1;29(21):2376-81. doi: 10.1097/01.brs.0000143667.55696.bd. Spine (Phila Pa 1976). 2004. PMID: 15507798
-
Incidence and risk factors of adjacent segment disease following posterior decompression and instrumented fusion for degenerative lumbar disorders.Medicine (Baltimore). 2017 Feb;96(5):e6032. doi: 10.1097/MD.0000000000006032. Medicine (Baltimore). 2017. PMID: 28151909 Free PMC article.
-
[Present clinical research situation of adjacent segment degeneration after lumbar spinal fusion].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2013 Jan;27(1):110-5. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2013. PMID: 23427505 Review. Chinese.
-
Adjacent segment degeneration following spinal fusion for degenerative disc disease.Bull NYU Hosp Jt Dis. 2007;65(1):29-36. Bull NYU Hosp Jt Dis. 2007. PMID: 17539759 Review. No abstract available.
Cited by
-
Effects of cord pretension and stiffness of the Dynesys system spacer on the biomechanics of spinal decompression- a finite element study.BMC Musculoskelet Disord. 2013 Jun 19;14:191. doi: 10.1186/1471-2474-14-191. BMC Musculoskelet Disord. 2013. PMID: 23777265 Free PMC article.
-
A Retrospective Observational Study to Evaluate Adjacent Segmental Degenerative Change with the Dynesys-Transition-Optima Instrumentation System.J Clin Med. 2024 Jan 19;13(2):582. doi: 10.3390/jcm13020582. J Clin Med. 2024. PMID: 38276088 Free PMC article.
-
Does Percutaneous Lumbosacral Pedicle Screw Instrumentation Prevent Long-Term Adjacent Segment Disease after Lumbar Fusion?Asian Spine J. 2021 Jun;15(3):301-307. doi: 10.31616/asj.2020.0157. Epub 2020 Sep 3. Asian Spine J. 2021. PMID: 32872750 Free PMC article.
-
Outcomes and Spinopelvic Changes After Anterior Lumbar Interbody Fusion With a Novel Interbody Fusion Device: A Retrospective Study.Int J Spine Surg. 2024 Sep 12;18(4):389-399. doi: 10.14444/8621. Int J Spine Surg. 2024. PMID: 39079745 Free PMC article.
-
Elastomeric Lumbar Total Disc Replacement: Clinical and Radiological Results With Minimum 84 Months Follow-Up.Int J Spine Surg. 2018 Mar 30;12(1):49-57. doi: 10.14444/5009. eCollection 2018 Jan. Int J Spine Surg. 2018. PMID: 30280083 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials