Maximum-likelihood estimation of low-rank signals for multiepoch MEG/EEG analysis
- PMID: 15536900
- DOI: 10.1109/TBME.2004.834285
Maximum-likelihood estimation of low-rank signals for multiepoch MEG/EEG analysis
Abstract
A maximum-likelihood-based algorithm is presented for reducing the effects of spatially colored noise in evoked response magneto- and electro-encephalography data. The repeated component of the data, or signal of interest, is modeled as the mean, while the noise is modeled as the Kronecker product of a spatial and a temporal covariance matrix. The temporal covariance matrix is assumed known or estimated prior to the application of the algorithm. The spatial covariance structure is estimated as part of the maximum-likelihood procedure. The mean matrix representing the signal of interest is assumed to be low-rank due to the temporal and spatial structure of the data. The maximum-likelihood estimates of the components of the low-rank signal structure are derived in order to estimate the signal component. The relationship between this approach and principal component analysis (PCA) is explored. In contrast to prestimulus-based whitening followed by PCA, the maximum-likelihood approach does not require signal-free data for noise whitening. Consequently, the maximum-likelihood approach is much more effective with nonstationary noise and produces better quality whitening for a given data record length. The efficacy of this approach is demonstrated using simulated and real MEG data.
Similar articles
-
Maximum likelihood dipole fitting in spatially colored noise.Neurol Clin Neurophysiol. 2004 Nov 30;2004:53. Neurol Clin Neurophysiol. 2004. PMID: 16012641
-
A maximum-likelihood estimator for trial-to-trial variations in noisy MEG/EEG data sets.IEEE Trans Biomed Eng. 2004 Dec;51(12):2123-8. doi: 10.1109/TBME.2004.836515. IEEE Trans Biomed Eng. 2004. PMID: 15605859
-
A resampling method for estimating the signal subspace of spatio-temporal EEG/MEG data.IEEE Trans Biomed Eng. 2003 Aug;50(8):935-49. doi: 10.1109/TBME.2003.814293. IEEE Trans Biomed Eng. 2003. PMID: 12892321
-
Joint decorrelation, a versatile tool for multichannel data analysis.Neuroimage. 2014 Sep;98:487-505. doi: 10.1016/j.neuroimage.2014.05.068. Epub 2014 Jun 2. Neuroimage. 2014. PMID: 24990357 Review.
-
Real-time intraoperative neurophysiological monitoring.Methods. 2001 Oct;25(2):272-87. doi: 10.1006/meth.2001.1239. Methods. 2001. PMID: 11812210 Review.
Cited by
-
A spatiotemporal framework for MEG/EEG evoked response amplitude and latency variability estimation.IEEE Trans Biomed Eng. 2010 Mar;57(3):616-25. doi: 10.1109/TBME.2009.2032533. Epub 2009 Sep 29. IEEE Trans Biomed Eng. 2010. PMID: 19789097 Free PMC article.
-
Detection of T-wave alternans in fetal magnetocardiography using the generalized likelihood ratio test.IEEE Trans Biomed Eng. 2013 Sep;60(9):2393-400. doi: 10.1109/TBME.2013.2256907. Epub 2013 Apr 4. IEEE Trans Biomed Eng. 2013. PMID: 23568477 Free PMC article.
-
A graphical model for estimating stimulus-evoked brain responses from magnetoencephalography data with large background brain activity.Neuroimage. 2006 Apr 1;30(2):400-16. doi: 10.1016/j.neuroimage.2005.09.055. Epub 2005 Dec 19. Neuroimage. 2006. PMID: 16360320 Free PMC article.
-
A spatiotemporal framework for estimating trial-to-trial amplitude variation in event-related MEG/EEG.IEEE Trans Biomed Eng. 2009 Mar;56(3):633-45. doi: 10.1109/TBME.2008.2008423. Epub 2008 Oct 31. IEEE Trans Biomed Eng. 2009. PMID: 19272883 Free PMC article.
-
Fetal QT Interval Estimation Using Sequential Hypothesis Testing.IEEE Trans Biomed Eng. 2017 Nov;64(11):2704-2710. doi: 10.1109/TBME.2017.2661248. IEEE Trans Biomed Eng. 2017. PMID: 28182551 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources