Abstract
Purpose: To compare the performance of radiologists and of a computer-aided detection (CAD) algorithm for pulmonary nodule detection on thin-section thoracic computed tomographic (CT) scans.
Materials and methods: The study was approved by the institutional review board. The requirement of informed consent was waived. Twenty outpatients (age range, 15-91 years; mean, 64 years) were examined with chest CT (multi-detector row scanner, four detector rows, 1.25-mm section thickness, and 0.6-mm interval) for pulmonary nodules. Three radiologists independently analyzed CT scans, recorded the locus of each nodule candidate, and assigned each a confidence score. A CAD algorithm with parameters chosen by using cross validation was applied to the 20 scans. The reference standard was established by two experienced thoracic radiologists in consensus, with blind review of all nodule candidates and free search for additional nodules at a dedicated workstation for three-dimensional image analysis. True-positive (TP) and false-positive (FP) results and confidence levels were used to generate free-response receiver operating characteristic (ROC) plots. Double-reading performance was determined on the basis of TP detections by either reader.
Results: The 20 scans showed 195 noncalcified nodules with a diameter of 3 mm or more (reference reading). Area under the alternative free-response ROC curve was 0.54, 0.48, 0.55, and 0.36 for CAD and readers 1-3, respectively. Differences between reader 3 and CAD and between readers 2 and 3 were significant (P < .05); those between CAD and readers 1 and 2 were not significant. Mean sensitivity for individual readings was 50% (range, 41%-60%); double reading resulted in increase to 63% (range, 56%-67%). With CAD used at a threshold allowing only three FP detections per CT scan, mean sensitivity was increased to 76% (range, 73%-78%). CAD complemented individual readers by detecting additional nodules more effectively than did a second reader; CAD-reader weighted kappa values were significantly lower than reader-reader weighted kappa values (Wilcoxon rank sum test, P < .05).
Conclusion: With CAD used at a level allowing only three FP detections per CT scan, sensitivity was substantially higher than with conventional double reading.
(c) RSNA, 2004.
Similar articles
-
A cloud-based computer-aided detection system improves identification of lung nodules on computed tomography scans of patients with extra-thoracic malignancies.Eur Radiol. 2019 Jan;29(1):144-152. doi: 10.1007/s00330-018-5528-6. Epub 2018 Jun 15. Eur Radiol. 2019. PMID: 29948089
-
Computer-aided detection (CAD) in lung cancer screening at chest MDCT: ROC analysis of CAD versus radiologist performance.J Thorac Imaging. 2007 Aug;22(3):241-6. doi: 10.1097/RTI.0b013e318033aae8. J Thorac Imaging. 2007. PMID: 17721333
-
Commercially available computer-aided detection system for pulmonary nodules on thin-section images using 64 detectors-row CT: preliminary study of 48 cases.Acad Radiol. 2009 Aug;16(8):924-33. doi: 10.1016/j.acra.2009.01.030. Epub 2009 Apr 25. Acad Radiol. 2009. PMID: 19394873
-
Software with artificial intelligence-derived algorithms for detecting and analysing lung nodules in CT scans: systematic review and economic evaluation.Health Technol Assess. 2025 May;29(14):1-234. doi: 10.3310/JYTW8921. Health Technol Assess. 2025. PMID: 40380885 Free PMC article.
-
Recent progress in computer-aided diagnosis of lung nodules on thin-section CT.Comput Med Imaging Graph. 2007 Jun-Jul;31(4-5):248-57. doi: 10.1016/j.compmedimag.2007.02.005. Epub 2007 Mar 21. Comput Med Imaging Graph. 2007. PMID: 17369020 Free PMC article. Review.
Cited by
-
Attitudes Of Chinese Cancer Patients Toward The Clinical Use Of Artificial Intelligence.Patient Prefer Adherence. 2019 Nov 1;13:1867-1875. doi: 10.2147/PPA.S225952. eCollection 2019. Patient Prefer Adherence. 2019. PMID: 31802856 Free PMC article.
-
A cloud-based computer-aided detection system improves identification of lung nodules on computed tomography scans of patients with extra-thoracic malignancies.Eur Radiol. 2019 Jan;29(1):144-152. doi: 10.1007/s00330-018-5528-6. Epub 2018 Jun 15. Eur Radiol. 2019. PMID: 29948089
-
Computer-aided detection of pulmonary nodules: a comparative study using the public LIDC/IDRI database.Eur Radiol. 2016 Jul;26(7):2139-47. doi: 10.1007/s00330-015-4030-7. Epub 2015 Oct 6. Eur Radiol. 2016. PMID: 26443601 Free PMC article.
-
Efficacy of computer-aided diagnosis in lung cancer screening with low-dose spiral computed tomography: receiver operating characteristic analysis of radiologists' performance.Jpn J Radiol. 2010 Nov;28(9):649-55. doi: 10.1007/s11604-010-0486-1. Epub 2010 Nov 27. Jpn J Radiol. 2010. PMID: 21113748
-
Accuracy of MRI volume measurements of breast lesions: comparison between automated, semiautomated and manual assessment.Eur Radiol. 2009 May;19(5):1097-107. doi: 10.1007/s00330-008-1243-z. Epub 2009 Jan 22. Eur Radiol. 2009. PMID: 19159935
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous