Objective: The purpose of this study was to investigate the potential use of low-tube-current MDCT virtual bronchoscopy for the evaluation of children with suspected foreign body aspiration.
Subjects and methods: Low-tube-current MDCT was performed in 23 patients (10 girls, 13 boys) with a mean age of 3.3 years (9 months-13 years) with suspicion of foreign body aspiration. Chest radiographs were obtained before CT was performed. MDCT was performed using 25- to 50-mA tube currents. MDCT virtual bronchoscopy images were obtained. Neither sedation nor IV contrast medium was used during CT scanning. All patients underwent endoscopic evaluation within 24 hr after MDCT was performed. MDCT virtual bronchoscopy findings were retrospectively compared with the results of rigid bronchoscopy.
Results: The mean tube current was 35 mA (range, 25-50 mA). Imaging quality was excellent in nine studies (39%), good in 12 studies (52%), and poor in two studies (9%). Motion artifacts were present on several slices in five examinations. In 15 patients, all foreign bodies detected by conventional bronchoscopy were also revealed on MDCT virtual bronchoscopy. The foreign body was in the right main bronchus in six patients, in the bronchus intermedius in one patient, and in the left main bronchus in eight patients. No discordance was found between the two techniques. MDCT revealed hyperaeration of the ipsilateral lung in five patients, atelectasis in five patients, infiltration in three patients, and infiltration and bronchiectasis in two patients; it showed infiltration in four patients and atelectasis in one of eight patients without a foreign body detected. There were no abnormal findings in three patients.
Conclusion: Evaluation of foreign body aspiration of the airway in children can be accomplished by using a low-tube-current MDCT protocol. It may be useful both in showing the exact location of a foreign body before bronchoscopy and in ruling out a foreign body in patients with a low level of suspicion and normal or nonspecific findings on chest radiography.
Comment in
-
CT dose reduction in pediatric patients.AJR Am J Roentgenol. 2005 May;184(5):1706; author reply 1706-7. doi: 10.2214/ajr.184.5.01841706. AJR Am J Roentgenol. 2005. PMID: 15855143 No abstract available.
Similar articles
-
Utilization of low-dose multidetector CT and virtual bronchoscopy in children with suspected foreign body aspiration.Pediatr Radiol. 2007 Jan;37(1):33-40. doi: 10.1007/s00247-006-0331-y. Epub 2006 Oct 11. Pediatr Radiol. 2007. PMID: 17033800
-
CT virtual bronchoscopy in the evaluation of children with suspected foreign body aspiration.Eur J Radiol. 2003 Nov;48(2):188-92. doi: 10.1016/S0720-048X(02)00295-4. Eur J Radiol. 2003. PMID: 14680912
-
Thin-section axial multidetector computed tomography and multiplanar reformatted imaging of children with suspected foreign-body aspiration: Is virtual bronchoscopy overemphasized?Acta Radiol. 2006 Sep;47(7):746-51. doi: 10.1080/02841850600803834. Acta Radiol. 2006. PMID: 16950716
-
Role of virtual bronchoscopy in children with a vegetable foreign body in the tracheobronchial tree.J Laryngol Otol. 2014 Dec;128(12):1078-83. doi: 10.1017/S0022215114002837. Epub 2014 Nov 12. J Laryngol Otol. 2014. PMID: 25388230 Review.
-
Use of virtual bronchoscopy in children with suspected foreign body aspiration.J Bras Pneumol. 2009 Sep;35(9):937-41. doi: 10.1590/s1806-37132009000900016. J Bras Pneumol. 2009. PMID: 19820821 Review. English, Portuguese.
Cited by
-
CT evaluation of airway foreign bodies in children: emphasis on the delayed diagnosis and differentiation from airway mucus plugs.Jpn J Radiol. 2013 Jan;31(1):31-8. doi: 10.1007/s11604-012-0141-0. Epub 2012 Oct 18. Jpn J Radiol. 2013. PMID: 23073821
-
Clinical variables responsible for early and late diagnosis of foreign body aspiration in pediatrics age group.J Cardiothorac Surg. 2020 Sep 29;15(1):271. doi: 10.1186/s13019-020-01314-9. J Cardiothorac Surg. 2020. PMID: 32993750 Free PMC article.
-
Diagnostic Value of Chest Computed Tomography Scan for Identification of Foreign Body Aspiration in Children: A Systematic Review and Meta-analysis.Arch Acad Emerg Med. 2024 Sep 5;13(1):e3. doi: 10.22037/aaem.v12i1.2431. eCollection 2025. Arch Acad Emerg Med. 2024. PMID: 39318866 Free PMC article. Review.
-
Identification of aspirated radiolucent foreign bodies in the pediatric airway using digital tomosynthesis: a multireader phantom study.J Med Imaging (Bellingham). 2020 Sep;7(5):055502. doi: 10.1117/1.JMI.7.5.055502. Epub 2020 Oct 28. J Med Imaging (Bellingham). 2020. PMID: 37476354 Free PMC article.
-
Utilization of low-dose multidetector CT and virtual bronchoscopy in children with suspected foreign body aspiration.Pediatr Radiol. 2007 Jan;37(1):33-40. doi: 10.1007/s00247-006-0331-y. Epub 2006 Oct 11. Pediatr Radiol. 2007. PMID: 17033800
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical