Artifact reduction using parallel imaging methods
- PMID: 15548957
- DOI: 10.1097/01.rmr.0000143782.39690.8a
Artifact reduction using parallel imaging methods
Abstract
Multiple receiver coils produce images with different but complementary views of a patient. This can be used to shorten scans times but there often remain image artifacts caused by patient motion or physiological processes such as flowing blood. This paper reviews how the extra information from the multiple coils can be used to reduce image artifacts. In one method, affected portions of data can be identified and discarded but enough information is still available to reconstruct an improved image. In other methods, the motion itself is determined and the corrupted data is then corrected, leading to an image with reduced artifacts. Results are presented from images corrupted by motion or by flowing blood.
Similar articles
-
POCS-enhanced correction of motion artifacts in parallel MRI.Magn Reson Med. 2010 Apr;63(4):1104-10. doi: 10.1002/mrm.22254. Magn Reson Med. 2010. PMID: 20373413 Free PMC article.
-
TSE with average-specific phase encoding ordering for motion detection and artifact suppression.J Magn Reson Imaging. 2007 Jun;25(6):1271-82. doi: 10.1002/jmri.20908. J Magn Reson Imaging. 2007. PMID: 17520734
-
Coil-based artifact reduction.Magn Reson Med. 2004 Oct;52(4):825-30. doi: 10.1002/mrm.20226. Magn Reson Med. 2004. PMID: 15389945
-
Parallel MR imaging.J Magn Reson Imaging. 2012 Jul;36(1):55-72. doi: 10.1002/jmri.23639. J Magn Reson Imaging. 2012. PMID: 22696125 Free PMC article. Review.
-
Motion artifacts in brain and spine MR.Radiol Clin North Am. 1988 Jul;26(4):737-53. Radiol Clin North Am. 1988. PMID: 3289073 Review.
Cited by
-
Motion-compensation techniques in neonatal and fetal MR imaging.AJNR Am J Neuroradiol. 2013 Jun-Jul;34(6):1124-36. doi: 10.3174/ajnr.A3128. Epub 2012 May 10. AJNR Am J Neuroradiol. 2013. PMID: 22576885 Free PMC article. Review.
-
Rigid-body motion correction with self-navigation MRI.Magn Reson Med. 2009 Mar;61(3):739-47. doi: 10.1002/mrm.21883. Magn Reson Med. 2009. PMID: 19097240 Free PMC article.
-
Off-resonance artifact correction for MRI: A review.NMR Biomed. 2023 May;36(5):e4867. doi: 10.1002/nbm.4867. Epub 2022 Dec 14. NMR Biomed. 2023. PMID: 36326709 Free PMC article. Review.
-
Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction.Magn Reson Med. 2013 Oct;70(4):1005-15. doi: 10.1002/mrm.24538. Epub 2012 Nov 6. Magn Reson Med. 2013. PMID: 23132549 Free PMC article.
-
Intrinsic detection of motion in segmented sequences.Magn Reson Med. 2011 Apr;65(4):1084-9. doi: 10.1002/mrm.22681. Epub 2010 Nov 3. Magn Reson Med. 2011. PMID: 21413072 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical