Influence of left ventricular function on outcome of patients treated with implantable defibrillators
- PMID: 1555274
- DOI: 10.1161/01.cir.85.4.1304
Influence of left ventricular function on outcome of patients treated with implantable defibrillators
Abstract
Background: The outcomes of patients treated with implantable defibrillators were compared between patients with left ventricular ejection fraction greater than or equal to 30% and less than 30%.
Methods and results: Of 68 consecutive patients treated with implantable defibrillators, 40 patients (group 1) had left ventricular ejection fraction greater than or equal to 30%, and 28 patients (group 2) had left ventricular ejection fraction less than 30%. Sudden death, surgical mortality, nonsudden arrhythmia-related death (death within 24 hours after an arrhythmic event despite initial termination of the arrhythmia by the implantable defibrillator), total arrhythmia-related death (including sudden death, surgical death, and nonsudden arrhythmia-related death), and total cardiac death were compared between the two groups. Surgical mortality was 4.4% (0% in group 1, 11% in group 2). During the follow-up of 31 +/- 27 months, actuarial survival rates free of events were 97%, 97%, and 97% in group 1 and 96%, 91%, and 82% in group 2 at 12, 24, and 36 months, respectively, for sudden death (p = NS); 97%, 97%, and 97% in group 1 and 85%, 81%, and 72% in group 2 at 12, 24, and 36 months, respectively, for sudden death and surgical mortality (p less than 0.05); 97%, 97%, and 97% in group 1 and 82%, 78%, and 70% in group 2 at 12, 24, and 36 months, respectively, for total arrhythmia-related death (p less than 0.05); and 95%, 95%, and 95% in group 1 and 82%, 69%, and 57% in group 2 at 12, 24, and 36 months, respectively, for total cardiac death (p less than 0.05). Four (57%) of seven nonsudden cardiac deaths during the initial 36-month follow-up period were causally related to arrhythmia (three surgical deaths and one arrhythmia-related nonsudden death).
Conclusions: The outcome of patients treated with implantable defibrillators is strongly influenced by the degree of left ventricular dysfunction. In group 1 patients, surgical mortality, sudden death, and total cardiac death are rare. In group 2, sudden death rate may not be markedly different from that of group 1 patients. However, the risk of therapy (surgical mortality) is high. Many nonsudden cardiac deaths are causally related to arrhythmia (surgical mortality or nonsudden arrhythmia-related death). Therefore, the survival rate free of total arrhythmia-related death is significantly lower in group 2 (70% versus 97% in group 1 at 3 years). Further studies are needed to determine the roles of defibrillator therapy and other therapies in various clinical settings.
Comment in
-
Defibrillators and ventricular dysfunction.Circulation. 1992 Nov;86(5):1660-1. doi: 10.1161/01.cir.86.5.1660. Circulation. 1992. PMID: 1423982 No abstract available.
-
Survival of implantable cardioverter-defibrillator recipients. Can the iceberg remain submerged?Circulation. 1992 Apr;85(4):1616-8. doi: 10.1161/01.cir.85.4.1616. Circulation. 1992. PMID: 1555299 No abstract available.
-
Mortality and implantable cardioverter-defibrillators.Circulation. 1993 Jul;88(1):332-4. Circulation. 1993. PMID: 8319350 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous