Radiosensitivity of children: potential for overexposure in CR and DR and magnitude of doses in ordinary radiographic examinations
- PMID: 15558258
- DOI: 10.1007/s00247-004-1266-9
Radiosensitivity of children: potential for overexposure in CR and DR and magnitude of doses in ordinary radiographic examinations
Abstract
The linear, no-threshold model is currently the best estimate of risk from radiation exposure with no level below which radiation is safe. Plain-film radiography has a much lower patient dose than CT or fluoroscopy. With the advent of computed radiography (CR) the dose to patients is higher than screen-film radiography and overexposure is quite common. Task-oriented adjustment of technique, commonly used in CT, is rarely used in CR. Exposure reduction is important in CR as research indicates an increased risk of childhood acute lymphocytic leukemia from plain-film studies and an increased risk of fatal breast cancer from scoliosis series. Future needs include better documentation of the dose the patient receives, dose-based research on the radiation risk, and accreditation in CR and digital radiography for public assurance.
Similar articles
-
Strategies for dose reduction in ordinary radiographic examinations using CR and DR.Pediatr Radiol. 2004 Oct;34 Suppl 3:S196-200; discussion S234-41. doi: 10.1007/s00247-004-1269-6. Pediatr Radiol. 2004. PMID: 15558261 Review.
-
Assessment of the problem: pediatric doses in screen-film and digital radiography.Pediatr Radiol. 2004 Oct;34 Suppl 3:S173-82; discussion S234-41. doi: 10.1007/s00247-004-1267-8. Pediatr Radiol. 2004. PMID: 15558259 Review.
-
Management of pediatric radiation dose using Agfa computed radiography.Pediatr Radiol. 2004 Oct;34 Suppl 3:S207-14; discussion S234-41. doi: 10.1007/s00247-004-1271-z. Pediatr Radiol. 2004. PMID: 15558263
-
Radiation, thoracic imaging, and children: radiation safety.Radiol Clin North Am. 2011 Sep;49(5):1053-69. doi: 10.1016/j.rcl.2011.06.003. Radiol Clin North Am. 2011. PMID: 21889021 Review.
-
Patient dose in digital projection radiography.Radiat Prot Dosimetry. 2008;129(1-3):135-7. doi: 10.1093/rpd/ncn013. Epub 2008 Feb 5. Radiat Prot Dosimetry. 2008. PMID: 18252850
Cited by
-
Unnecessary irradiation to non-thoracic structures during pediatric chest radiography.Pediatr Radiol. 2006 Jan;36(1):22-5. doi: 10.1007/s00247-005-0016-y. Epub 2005 Oct 21. Pediatr Radiol. 2006. PMID: 16240140
-
Preoperative imaging of clinically relevant intrathoracic abnormalities in pectus excavatum patients.Quant Imaging Med Surg. 2023 Jun 1;13(6):3489-3495. doi: 10.21037/qims-22-1366. Epub 2023 Mar 27. Quant Imaging Med Surg. 2023. PMID: 37284105 Free PMC article.
-
Female gonadal shielding with automatic exposure control increases radiation risks.Pediatr Radiol. 2018 Feb;48(2):227-234. doi: 10.1007/s00247-017-3996-5. Epub 2017 Oct 18. Pediatr Radiol. 2018. PMID: 29046919
-
Radiation safety.Pediatr Radiol. 2009 Jun;39 Suppl 3:385-90. doi: 10.1007/s00247-009-1215-8. Pediatr Radiol. 2009. PMID: 19440758 Review. No abstract available.
-
Pediatric radiography entrance doses for some routine procedures in three hospitals within eastern Nigeria.J Med Phys. 2008 Jan;33(1):29-34. doi: 10.4103/0971-6203.39422. J Med Phys. 2008. PMID: 20041050 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical