Management of pediatric radiation dose using Agfa computed radiography
- PMID: 15558263
- DOI: 10.1007/s00247-004-1271-z
Management of pediatric radiation dose using Agfa computed radiography
Abstract
Radiation dose to patients and its management have become important considerations in modern radiographic imaging procedures, but they acquire particular significance in the imaging of children. Because of their longer life expectancy, children exposed to radiation are thought to have a significantly increased risk of radiation-related late sequelae compared to adults first exposed to radiation later in life. Therefore, current clinical thinking dictates that dose in pediatric radiography be minimized, while simultaneously ensuring sufficient diagnostic information in the image, and reducing the need for repeat exposures. Dose management obviously starts with characterization and control of the exposure technique. However, it extends farther through the imaging chain to the acquisition system, and even to the image processing techniques used to optimize acquired images for display. Further, other factors, such as quality control procedures and the ability to handle special pediatric procedures, like scoliosis exams, also come into play. The need for dose management in modern radiography systems has spawned a variety of different solutions, some of which are similar across different manufacturers, and some of which are unique. This paper covers the techniques used in Agfa Computed Radiography (CR) systems to manage dose in a pediatric environment.
Similar articles
-
Strategies for dose reduction in ordinary radiographic examinations using CR and DR.Pediatr Radiol. 2004 Oct;34 Suppl 3:S196-200; discussion S234-41. doi: 10.1007/s00247-004-1269-6. Pediatr Radiol. 2004. PMID: 15558261 Review.
-
Management of pediatric radiation dose using GE's Revolution digital radiography systems.Pediatr Radiol. 2004 Oct;34 Suppl 3:S215-20; discussion S234-41. doi: 10.1007/s00247-004-1272-y. Pediatr Radiol. 2004. PMID: 15558264
-
Management of pediatric radiation dose using Philips digital radiography.Pediatr Radiol. 2004 Oct;34 Suppl 3:S227-33; discussion S234-41. doi: 10.1007/s00247-004-1274-9. Pediatr Radiol. 2004. PMID: 15558266
-
Advances in computed radiography systems and their physical imaging characteristics.Clin Radiol. 2007 Dec;62(12):1132-41. doi: 10.1016/j.crad.2007.07.009. Epub 2007 Sep 7. Clin Radiol. 2007. PMID: 17981160 Review.
-
Management of pediatric radiation dose using Fuji computed radiography.Pediatr Radiol. 2004 Oct;34 Suppl 3:S201-6; discussion S234-41. doi: 10.1007/s00247-004-1270-0. Pediatr Radiol. 2004. PMID: 15558262
Cited by
-
Quality assurance: a comparison study of radiographic exposure for neonatal chest radiographs at 4 academic hospitals.Pediatr Radiol. 2012 Jun;42(6):668-73. doi: 10.1007/s00247-011-2290-1. Epub 2011 Nov 6. Pediatr Radiol. 2012. PMID: 22057362
-
An artificial intelligence model for predicting an appropriate mAs with target exposure indicator for chest digital radiography.Sci Rep. 2025 Apr 8;15(1):11942. doi: 10.1038/s41598-025-96947-y. Sci Rep. 2025. PMID: 40200108 Free PMC article.
-
Estimating Thyroid Doses From Modified Barium Swallow Studies.Health Phys. 2018 Sep;115(3):360-368. doi: 10.1097/HP.0000000000000890. Health Phys. 2018. PMID: 30045116 Free PMC article.
-
Letter to the editor re: "Optimizing the use of computer radiography in pediatric chest imaging".J Digit Imaging. 2009 Apr;22(2):99-100; author reply 101-2. doi: 10.1007/s10278-008-9137-9. Epub 2008 Jul 12. J Digit Imaging. 2009. PMID: 18622641 Free PMC article. No abstract available.
-
Optimising the use of computed radiography in pediatric chest imaging.J Digit Imaging. 2009 Apr;22(2):104-13. doi: 10.1007/s10278-007-9071-2. Epub 2007 Sep 13. J Digit Imaging. 2009. PMID: 17851716 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical