Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Nov;11(11):1219-28.
doi: 10.1016/j.acra.2004.07.015.

Gadolinium contrast media are more nephrotoxic than a low osmolar iodine medium employing doses with equal X-ray attenuation in renal arteriography: an experimental study in pigs

Affiliations
Comparative Study

Gadolinium contrast media are more nephrotoxic than a low osmolar iodine medium employing doses with equal X-ray attenuation in renal arteriography: an experimental study in pigs

Barbara Elmståhl et al. Acad Radiol. 2004 Nov.

Abstract

Rationale and objectives: To investigate in a unilaterally nephrectomized porcine model whether gadolinium contrast media (Gd-CM) are less nephrotoxic than iodine media (I-CM) in x-ray arteriography of a kidney made temporarily ischemic by arterial balloon occlusion.

Materials and methods: In a noncrossover design, 3 mL of each test solution were injected in eight pigs (mean weight 19 kg) at a rate of 20 mL/min into the right renal artery at the start of a 10-minute period of ischemia. In group 1 (40 pigs) we injected 0.5 M gadopentetate, 0.5 M gadodiamide, 0.5 M iohexol (190 mg I/mL), 0.18 M iohexol (70 mg I/mL; with an x-ray attenuation equal to that of 0.5 M Gd-CM at 80 kV), and saline. In group 2 (24 pigs), we tested 0.18 M iohexol with ischemia and saline with and without ischemia. Gd- and iodine contrast media functioned as markers of glomerular filtration rate (GFR). When saline was tested, a low dose of iohexol (3 mL per pig; 300 mg I/mL) was injected as GFR marker intravenously in group 1 and into the renal artery in group 2. The plasma half-life elimination times of the CM 1-3 hours after injection were used to compare the effects of the different test solutions on GFR. Longer half-life means lower GFR.

Results: Group 1: median plasma half-life elimination time of the GFR marker was 3 340 minutes after injection of 0.5 M gadopentetate, 256 after 0.5 M gadodiamide, 179 after 0.5 M iohexol, 143 after 0.18 M iohexol, and 133 minutes after saline. All differences except that between 0.18 M iohexol and saline were statistically significant (P < .01). Group 2: median plasma half-life was 174 minutes after 0.18 M iohexol with ischemia, 196 minutes after saline with ischemia, and 195 minutes after saline without ischemia. There were no significant differences between the test solutions in group 2 (P > .05).

Conclusion: In pigs, 0.5 M Gd-CM were more nephrotoxic than both equal-attenuating (70 mg I/mL) and equimolar (190 mg I/mL) concentrations of the I-CM iohexol. These results do not support the "off-label" use of Gd-CM for renal x-ray arteriography in man instead of commercially available concentrations of iodine contrast media at 140, 150 and 180 mg I/mL or diluted to 70 mg I/mL.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources