[Computerized tomography of the liver. Accuracy of the method in biopsy proven diagnoses (author's transl)]
- PMID: 155617
- DOI: 10.1055/s-0029-1231325
[Computerized tomography of the liver. Accuracy of the method in biopsy proven diagnoses (author's transl)]
Abstract
To evaluate the diagnostic accuracy of computerized tomography (CT) in detecting liver disease, CT-findings of 320 patients examined with a slow CT-scanner (2.5 min scanning time/slice) could be compared to the results of bioptic procedures. Sensitivity was 81% for circumscript liver disease, specificity was 85%. In 69% of the cases, a type-specific diagnosis of circumscript liver diseases was possible, this percentage increased by 5% if patients with a true-positive differential diagnosis were included. 73% of the patients with liver metastases were correctly identified to have metastatic liver disease. Obstructive jaundice was correctly identified in 77% and correctly excluded in all patients with medical jaundice. For a large variety of hepatocellular disease, ratio of true positive diagnoses was 16% only. The value of CT in hepatocellular disease concerns exclusion of presumed space-occupying lesions. In a control group of 310 patients with only "clinically" and not bioptically confirmed diagnoses, specificity was 96% and sensitivity concerning focal liver disease was 82%. Our results prove CT to be a valuable non-invasive tool in the evaluation of circumscript liver disease.
Similar articles
-
Computerized tomography and nuclear imaging of the liver: a comparative study in 83 cases.Eur J Nucl Med. 1978 Apr 1;3(2):71-80. doi: 10.1007/BF00251627. Eur J Nucl Med. 1978. PMID: 750203
-
Diagnostic accuracy of CT in circumscript liver disease.AJR Am J Roentgenol. 1978 Apr;130(4):711-4. doi: 10.2214/ajr.130.4.711. AJR Am J Roentgenol. 1978. PMID: 205125
-
Accuracy of computed tomography of the liver and biliary tract.Radiology. 1977 Jul;124(1):123-8. doi: 10.1148/124.1.123. Radiology. 1977. PMID: 194273
-
The spectrum of liver disease on CT.J Can Assoc Radiol. 1979 Dec;30(4):211-5. J Can Assoc Radiol. 1979. PMID: 389936 Review.
-
[Can triphasic spiral CT provide data for the histologic characterization of liver masses?].Clin Ter. 2000 Mar-Apr;151(2):103-10. Clin Ter. 2000. PMID: 10876978 Review. Italian.
Cited by
-
Correlation of abdominal CT imaging with autopsy findings in patients with malignant tumors.J Cancer Res Clin Oncol. 1987;113(3):279-84. doi: 10.1007/BF00396386. J Cancer Res Clin Oncol. 1987. PMID: 3584217 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources