Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2004 Dec;17(12):1266-74.
doi: 10.1016/j.echo.2004.08.028.

Assessment of propagation velocity by contrast echocardiography for standardization of color Doppler propagation velocity measurements

Affiliations
Comparative Study

Assessment of propagation velocity by contrast echocardiography for standardization of color Doppler propagation velocity measurements

Yoshihiro Seo et al. J Am Soc Echocardiogr. 2004 Dec.

Abstract

Background: Color Doppler propagation velocity (Vp) (color-Vp) has not yet been standardized, although it should be able to specifically reflect the intraventricular movements of left ventricular (LV) inflow. Because contrast echocardiography can depict a specified flow, we used this modality to standardize measurements of color-Vp of LV inflow.

Methods: We performed contrast echocardiographic examinations in 100 patients (70 men, 30 women; age 53 +/- 12 years). Four types of color-Vp were measured: by the flow wave front method and by aliasing method using 3 aliasing velocity levels based on the peak velocity of early diastolic flow of transmitral flow. We also determined contrast echocardiographic Vp by M-mode imaging of LV inflow (contrast-Vp).

Results: Contrast-Vp and all 4 types of color-Vp could be compared in 86 patients. Contrast-Vp was significantly lower than color-Vp ( P < .01), except for color-Vp measured at the aliasing level 50% > peak velocity of early diastolic flow >/= 40% (color-Vp 40). A close relationship was observed between contrast-Vp and color-Vp 40 ( r = 0.801, P < .0001). Contrast-Vp and color-Vp 40 showed high ability to detect abnormal transmitral flow patterns according to receiver operating characteristics curves (area under curve for contrast-Vp, 0.94; for color-Vp 40, 0.90).

Conclusions: Our results should be useful in standardization of color-Vp measurement to specifically reflect propagation of the fluid elements derived from LV inflow, with ability to distinguish LV filling abnormalities.