Performance of electrokinetic supercharging for high-sensitivity detection of DNA fragments in chip gel electrophoresis
- PMID: 15565672
- DOI: 10.1002/elps.200406061
Performance of electrokinetic supercharging for high-sensitivity detection of DNA fragments in chip gel electrophoresis
Abstract
Chip gel electrophoresis was explored for high-sensitivity detection of DNA by combining electrokinetic injection with transient isotachophoresis preconcentration (here named electrokinetic supercharging (EKS)). Low concentrations (0.2 mg/L) of DNA sample could be detected without fluorescence labeling using a conventional UV detector (at 260 nm). On a single-channel microchip, identification of PCR product was performed by exploiting both external and internal calibration methods. The deviation between the two calibration methods was about 3.6%, and the identified DNA fragment size matched with the predicted size of the template DNA. On the cross microchip the EKS preconcentration has also been achieved when changing the injection reservoir differing from the one used previously. The procedure was computer-simulated and the influence of the voltage applied to two-side reservoirs on sample preconcentration and dilution was also discussed.
Similar articles
-
Optimization of the electrokinetic supercharging preconcentration for high-sensitivity microchip gel electrophoresis on a cross-geometry microchip.Electrophoresis. 2004 Jul;25(14):2357-62. doi: 10.1002/elps.200305910. Electrophoresis. 2004. PMID: 15274018
-
Study of a novel sample injection method (floating electrokinetic supercharging) for high-performance microchip electrophoresis of DNA fragments.Electrophoresis. 2008 May;29(9):1829-35. doi: 10.1002/elps.200700590. Electrophoresis. 2008. PMID: 18393341
-
High-sensitivity capillary and microchip electrophoresis using electrokinetic supercharging preconcentration. Insight into the stacking mechanism via computer modeling.J Chromatogr A. 2009 Jan 23;1216(4):660-70. doi: 10.1016/j.chroma.2008.10.077. Epub 2008 Oct 25. J Chromatogr A. 2009. PMID: 18996535 Review.
-
Impact of reservoir potentials on the analyte behavior in microchip electrophoresis: computer simulation and experimental validation for DNA fragments.Electrophoresis. 2005 Jan;26(2):383-90. doi: 10.1002/elps.200410151. Electrophoresis. 2005. PMID: 15657886
-
High-sensitivity capillary and microchip electrophoresis using electrokinetic supercharging.J Sep Sci. 2011 Oct;34(20):2790-9. doi: 10.1002/jssc.201100384. Epub 2011 Jul 27. J Sep Sci. 2011. PMID: 21793208 Review.
Cited by
-
CE-MS with electrokinetic supercharging and application to determination of neurotransmitters.Electrophoresis. 2019 Nov;40(22):2946-2953. doi: 10.1002/elps.201900203. Epub 2019 Oct 1. Electrophoresis. 2019. PMID: 31502303 Free PMC article.
-
Recent developments in optical detection methods for microchip separations.Anal Bioanal Chem. 2007 Jan;387(1):183-92. doi: 10.1007/s00216-006-0820-8. Epub 2006 Oct 10. Anal Bioanal Chem. 2007. PMID: 17031620 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources