Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis
- PMID: 15565719
- DOI: 10.1002/rcm.1738
Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis
Abstract
An ion mobility spectrometer that can easily be installed as an intermediate component between a commercial triple-quadrupole mass spectrometer and its original atmospheric pressure ionization (API) sources was developed. The curtain gas from the mass spectrometer is also used as the ion mobility spectrometer drift gas. The design of the ion mobility spectrometer allows reasonably fast installation (about 1 h), and thus the ion mobility spectrometer can be considered as an accessory of the mass spectrometer. The ion mobility spectrometer module can also be used as an independently operated device when equipped with a Faraday cup detector. The drift tube of the ion mobility spectrometer module consists of inlet, desolvation, drift, and extraction regions. The desolvation, drift and extraction regions are separated by ion gates. The inlet region has the shape of a stainless steel cup equipped with a small orifice. Ion mobility spectrometer drift gas is introduced through a curtain gas line from an original flange of the mass spectrometer. After passing through the drift tube, the drift gas serves as a curtain gas for the ion-sampling orifice of the ion mobility spectrometer before entering the ion source. Counterflow of the drift gas improves evaporation of the solvent from the electrosprayed sample. Drift gas is pumped away from the ion source through the original exhaust orifice of the ion source. Initial characterization of the ion mobility spectrometer device includes determination of resolving power values for a selected set of test compounds, separation of a simple mixture, and comparison of the sensitivity of the electrospray ionization ion mobility spectrometry/mass spectrometry (ESI-IMS/MS) mode with that of the ESI-MS mode. A resolving power of 80 was measured for 2,6-di-tert-butylpyridine in a 333 V/cm drift field at room temperature and with a 0.2 ms ion gate opening time. The resolving power was shown to be dependent on drift gas flow rate for all studied ion gate opening times. Resolving power improved as the drift gas flow increased, e.g. at a 0.5 ms gate opening time, a resolving power of 31 was obtained with a 0.65 L/min flow rate and 47 with a 1.3 L/min flow rate for tetrabutylammonium iodide. The measured limits of detection with ESI-MS and with ESI-IMS/MS modes were similar, demonstrating that signal losses in the IMS device are minimal when it is operated in a continuous flow mode. Based on these preliminary results, the IMS/MS instrument is anticipated to have potential for fast screening analysis that can be applied, for example, in environmental and drug analysis.
Copyright 2004 John Wiley & Sons, Ltd.
Similar articles
-
Performance, resolving power, and radial ion distributions of a prototype nanoelectrospray ionization resistive glass atmospheric pressure ion mobility spectrometer.Anal Chem. 2007 Oct 15;79(20):7782-91. doi: 10.1021/ac071226o. Epub 2007 Sep 14. Anal Chem. 2007. PMID: 17854161
-
Interfacing an ion mobility spectrometry based explosive trace detector to a triple quadrupole mass spectrometer.Anal Chem. 2011 Nov 15;83(22):8596-603. doi: 10.1021/ac201999a. Epub 2011 Oct 21. Anal Chem. 2011. PMID: 22017332
-
Design for electrospray ionization-ion mobility spectrometry.Anal Chem. 2007 Apr 15;79(8):3199-205. doi: 10.1021/ac062381q. Epub 2007 Mar 17. Anal Chem. 2007. PMID: 17367117
-
Ion mobility spectrometry detection for gas chromatography.J Chromatogr A. 2008 Jan 4;1177(1):12-27. doi: 10.1016/j.chroma.2007.10.110. Epub 2007 Nov 12. J Chromatogr A. 2008. PMID: 18067900 Review.
-
Ion mobility-mass spectrometry.J Mass Spectrom. 2008 Jan;43(1):1-22. doi: 10.1002/jms.1383. J Mass Spectrom. 2008. PMID: 18200615 Review.
Cited by
-
Characterization of proton-bound acetate dimers in ion mobility spectrometry.J Am Soc Mass Spectrom. 2008 Sep;19(9):1361-6. doi: 10.1016/j.jasms.2008.05.024. Epub 2008 Jun 17. J Am Soc Mass Spectrom. 2008. PMID: 18635378
-
Separation of different ion structures in atmospheric pressure photoionization-ion mobility spectrometry-mass spectrometry (APPI-IMS-MS).J Am Soc Mass Spectrom. 2010 Sep;21(9):1565-72. doi: 10.1016/j.jasms.2010.04.018. Epub 2010 May 3. J Am Soc Mass Spectrom. 2010. PMID: 20605730
-
Development of an Ion Mobility Spectrometry-Orbitrap Mass Spectrometer Platform.Anal Chem. 2016 Dec 20;88(24):12152-12160. doi: 10.1021/acs.analchem.6b03027. Epub 2016 Dec 1. Anal Chem. 2016. PMID: 28193022 Free PMC article.
-
Ion Mobility Collision Cross Section Compendium.Anal Chem. 2017 Jan 17;89(2):1032-1044. doi: 10.1021/acs.analchem.6b04905. Epub 2016 Dec 28. Anal Chem. 2017. PMID: 28035808 Free PMC article. Review.
-
Characterizing electrospray ionization using atmospheric pressure ion mobility spectrometry.Anal Chem. 2006 Nov 15;78(22):7751-60. doi: 10.1021/ac0613380. Anal Chem. 2006. PMID: 17105168 Free PMC article.
LinkOut - more resources
Full Text Sources