Clinical gastrointestinal manometry studies are currently performed with multilumen water-perfused polyvinyl or strain gauge sensor solid-state catheters. A disposable catheter incorporating air-filled balloons has been developed with performance characteristics suitable for esophageal and anorectal manometry studies. Our aim was to compare esophageal and anorectal pressure measurements using this newly developed catheter with measurements obtained using standard solid-state or water-perfused catheters. Measurements of resting LES pressure, esophageal contraction amplitudes, and anorectal rest and squeeze pressures were obtained in 10 healthy volunteers using a solid-state esophageal catheter, a water-perfused anorectal catheter, and air-filled balloon esophageal and anorectal catheters. Correlation coefficient analysis demonstrated that LES pressures, esophageal contraction amplitudes, and anorectal resting and squeeze pressures were not significantly among between the different catheters. We conclude that recently developed air-filled balloon esophageal and anorectal manometry catheters provide very similar measurements of LES, esophageal body, and anorectal sphincter pressures compared to presently used manometry catheters.
Similar articles
-
High-resolution anorectal manometry: A comparison of solid-state and water-perfused catheters.Neurogastroenterol Motil. 2017 Nov;29(11). doi: 10.1111/nmo.13124. Epub 2017 Jun 22. Neurogastroenterol Motil. 2017. PMID: 28639425
-
Significant pressure differences between solid-state and water-perfused systems in lower esophageal sphincter measurement.Surg Endosc. 2015 Dec;29(12):3565-9. doi: 10.1007/s00464-015-4109-x. Epub 2015 Feb 21. Surg Endosc. 2015. PMID: 25701063
-
Stability and Agreement of a Microtransducer and an Air-Filled Balloon Esophageal Catheter in the Monitoring of Esophageal Pressure.Respir Care. 2017 Feb;62(2):215-221. doi: 10.4187/respcare.04849. Epub 2016 Oct 11. Respir Care. 2017. PMID: 27729399
-
Anorectal manometry: the state of the art.Dig Dis. 1993 Jul-Oct;11(4-5):252-64. doi: 10.1159/000171417. Dig Dis. 1993. PMID: 8222306 Review.
-
[Manometric data collection].Minerva Chir. 1991 Apr 15;46(7 Suppl):3-10. Minerva Chir. 1991. PMID: 2067692 Review. Italian.
Cited by
-
Expert consensus document: Advances in the evaluation of anorectal function.Nat Rev Gastroenterol Hepatol. 2018 May;15(5):309-323. doi: 10.1038/nrgastro.2018.27. Epub 2018 Apr 11. Nat Rev Gastroenterol Hepatol. 2018. PMID: 29636555 Free PMC article. Review.
-
Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women.Biomed Microdevices. 2012 Apr;14(2):347-55. doi: 10.1007/s10544-011-9611-x. Biomed Microdevices. 2012. PMID: 22147020 Free PMC article.
-
Development of a novel intra-vaginal transducer with improved dynamic response.Biomed Microdevices. 2009 Dec;11(6):1213-21. doi: 10.1007/s10544-009-9339-z. Biomed Microdevices. 2009. PMID: 19629699 Free PMC article.
-
Anorectal Manometry Versus Patient-Reported Outcome Measures as a Predictor of Maximal Treatment for Fecal Incontinence.Ann Coloproctol. 2019 Dec;35(6):319-326. doi: 10.3393/ac.2018.10.16. Epub 2019 Dec 31. Ann Coloproctol. 2019. PMID: 31937071 Free PMC article.
-
High-Resolution Anorectal Manometry - New Insights in the Diagnostic Assessment of Functional Anorectal Disorders.Visc Med. 2018 Apr;34(2):134-139. doi: 10.1159/000488611. Epub 2018 Apr 20. Visc Med. 2018. PMID: 29888243 Free PMC article. Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical