The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
- PMID: 15577460
The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
Abstract
The annual wear rate in polyethylene articulations should be 0.1 mm or less to avoid future osteolysis. Highly cross-linked polyethylene shows an 80 to 90% wear reduction in hip simulator testing, but the clinical documentation of this new polyethylene is still inadequate. We evaluated the highly cross-linked polyethylene in two prospective randomized clinical studies. Thirty-two patients (12 men, 20 women; 64 hips) with a median age of 48 years (range, 29-70 years) with bilateral primary or secondary arthrosis of the hip had hybrid total hip arthroplasty with liners made of highly cross-linked polyethylene on one side and conventional polyethylene on the other. Twenty-seven patients in this study have passed 2 years followup. A further group, comprised of 60 patients (61 hips) with a median age of 55 years (range, 35-70 years), was randomized to receive either highly cross-linked polyethylene or conventional cemented all-polyethylene of the same design. Forty-nine of these 60 patients have been observed for 3 years. In both studies all patients received Spectron stems with 28-mm Co-Cr heads. Radiostereometric examinations with the patient supine or standing were done at regular intervals. Wear was measured in the supine position from the first postoperative week, whereas standing examinations were initiated 3 months after the operation. The penetration rate almost was identical in the study and control groups at 6 months after the operation. Thereafter, the penetration rate leveled out in the two groups with highly cross-linked polyethylene. At 2 years the highly cross-linked polyethylene liner showed 62% lower proximal penetration and 31% lower total (three-dimensional) penetration when the patients were examined in supine position. The highly crosslinked all-polyethylene cemented cups showed lower proximal penetration in both positions. The better wear performance of highly cross-linked polyethylene could increase the implant longevity. Longer followup is needed to evaluate if this new material is associated with less occurrence of osteolysis.
Similar articles
-
New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.Acta Orthop Suppl. 2005 Feb;76(315):3-82. Acta Orthop Suppl. 2005. PMID: 15790289 Review.
-
Femoral Head Penetration of Vitamin E-Infused Highly Cross-Linked Polyethylene Liners: A Randomized Radiostereometric Study of Seventy Hips Followed for Two Years.J Bone Joint Surg Am. 2015 Aug 19;97(16):1366-71. doi: 10.2106/JBJS.N.00595. J Bone Joint Surg Am. 2015. PMID: 26290088 Clinical Trial.
-
Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.J Bone Joint Surg Am. 2015 Apr 15;97(8):627-34. doi: 10.2106/JBJS.N.00605. J Bone Joint Surg Am. 2015. PMID: 25878306 Free PMC article. Clinical Trial.
-
The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.J Bone Joint Surg Am. 2011 Apr 20;93(8):716-22. doi: 10.2106/JBJS.J.00287. J Bone Joint Surg Am. 2011. PMID: 21508278 Clinical Trial.
-
Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty.J Bone Joint Surg Am. 2007 Dec;89(12):2779-86. doi: 10.2106/JBJS.G.00043. J Bone Joint Surg Am. 2007. PMID: 18056513 Review.
Cited by
-
Total hip arthroplasty: Survival and modes of failure.EFORT Open Rev. 2018 May 21;3(5):232-239. doi: 10.1302/2058-5241.3.170068. eCollection 2018 May. EFORT Open Rev. 2018. PMID: 29951261 Free PMC article.
-
Study of the polycarbonate-urethane/metal contact in different positions during gait cycle.Biomed Res Int. 2014;2014:548968. doi: 10.1155/2014/548968. Epub 2014 Aug 27. Biomed Res Int. 2014. PMID: 25247180 Free PMC article.
-
Head, acetabular liner composition, and rate of revision and wear in total hip arthroplasty: a Bayesian network meta-analysis.Sci Rep. 2023 Nov 21;13(1):20327. doi: 10.1038/s41598-023-47670-z. Sci Rep. 2023. PMID: 37989863 Free PMC article.
-
Dislocation after total hip arthroplasty with 28 and 32-mm femoral head.J Orthop Traumatol. 2010 Jun;11(2):111-5. doi: 10.1007/s10195-010-0097-8. Epub 2010 May 27. J Orthop Traumatol. 2010. PMID: 20505973 Free PMC article.
-
[Implant wear and aseptic loosening. An overview].Orthopade. 2009 Aug;38(8):690-7. doi: 10.1007/s00132-009-1431-9. Orthopade. 2009. PMID: 19657620 Review. German.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical