. 2004 Nov;42(6):754-61.
doi: 10.1007/BF02345208.

Computer-based test-bed for clinical assessment of hand/wrist feed-forward neuroprosthetic controllers using artificial neural networks

Affiliations

Computer-based test-bed for clinical assessment of hand/wrist feed-forward neuroprosthetic controllers using artificial neural networks

J L Luján et al. Med Biol Eng Comput. 2004 Nov.

Abstract

Neuroprosthestic systems can be used to restore hand grasp and wrist control in individuals with C5/C6 spinal cord injury. A computer-based system was developed for the implementation, tuning and clinical assessment of neuroprosthetic controllers, using off-the-shelf hardware and software. The computer system turned a Pentium III PC running Windows NT into a non-dedicated, real-time system for the control of neuroprostheses. Software execution (written using the high-level programming languages LabVIEW and MATLAB) was divided into two phases: training and real-time control. During the training phase, the computer system collected input/output data by stimulating the muscles and measuring the muscle outputs in real-time, analysed the recorded data, generated a set of training data and trained an artificial neural network (ANN)-based controller. During real-time control, the computer system stimulated the muscles using stimulus pulsewidths predicted by the ANN controller in response to a sampled input from an external command source, to provide independent control of hand grasp and wrist posture. System timing was stable, reliable and capable of providing muscle stimulation at frequencies up to 24Hz. To demonstrate the application of the test-bed, an ANN-based controller was implemented with three inputs and two independent channels of stimulation. The ANN controller's ability to control hand grasp and wrist angle independently was assessed by quantitative comparison of the outputs of the stimulated muscles with a set of desired grasp or wrist postures determined by the command signal. Controller performance results were mixed, but the platform provided the tools to implement and assess future controller designs.

PubMed Disclaimer

Similar articles

Cited by

References

    1. IEEE Trans Biomed Eng. 1998 Apr;45(4):463-75 - PubMed
    1. IEEE Trans Biomed Eng. 1987 Jul;34(7):499-508 - PubMed
    1. Med Eng Phys. 2003 Jan;25(1):3-9 - PubMed
    1. IEEE Trans Rehabil Eng. 1999 Mar;7(1):69-79 - PubMed
    1. IEEE Trans Biomed Eng. 1995 Nov;42(11):1117-27 - PubMed

Publication types

LinkOut - more resources