Brain-computer interface (BCI) operation: signal and noise during early training sessions
- PMID: 15589184
- DOI: 10.1016/j.clinph.2004.07.004
Brain-computer interface (BCI) operation: signal and noise during early training sessions
Abstract
Objective: People can learn to control mu (8-12 Hz) or beta (18-25 Hz) rhythm amplitude in the electroencephalogram (EEG) recorded over sensorimotor cortex and use it to move a cursor to a target on a video screen. The recorded signal may also contain electromyogram (EMG) and other non-EEG artifacts. This study examines the presence and characteristics of EMG contamination during new users' initial brain-computer interface (BCI) training sessions, as they first attempt to acquire control over mu or beta rhythm amplitude and to use that control to move a cursor to a target.
Methods: In the standard one-dimensional format, a target appears along the right edge of the screen and 1s later the cursor appears in the middle of the left edge and moves across the screen at a fixed rate with its vertical movement controlled by a linear function of mu or beta rhythm amplitude. In the basic two-choice version, the target occupies the upper or lower half of the right edge. The user's task is to move the cursor vertically so that it hits the target when it reaches the right edge. The present data comprise the first 10 sessions of BCI training from each of 7 users. Their data were selected to illustrate the variations seen in EMG contamination across users.
Results: Five of the 7 users learned to change rhythm amplitude appropriately, so that the cursor hit the target. Three of these 5 showed no evidence of EMG contamination. In the other two of these 5, EMG was prominent in early sessions, and tended to be associated with errors rather than with hits. As EEG control improved over the 10 sessions, this EMG contamination disappeared. In the remaining two users, who never acquired actual EEG control, EMG was prominent in initial sessions and tended to move the cursor to the target. This EMG contamination was still detectable by Session 10.
Conclusions: EMG contamination arising from cranial muscles is often present early in BCI training and gradually wanes. In those users who eventually acquire EEG control, early target-related EMG contamination may be most prominent for unsuccessful trials, and may reflect user frustration. In those users who never acquire EEG control, EMG may initially serve to move the cursor toward the target. Careful and comprehensive topographical and spectral analyses throughout user training are essential for detecting EMG contamination and differentiating between cursor control provided by EEG control and cursor control provided by EMG contamination.
Significance: Artifacts such as EMG are common in EEG recordings. Comprehensive spectral and topographical analyses are necessary to detect them and ensure that they do not masquerade as, or interfere with acquisition of, actual EEG-based cursor control.
Similar articles
-
Sensorimotor rhythm-based brain-computer interface (BCI): feature selection by regression improves performance.IEEE Trans Neural Syst Rehabil Eng. 2005 Sep;13(3):372-9. doi: 10.1109/TNSRE.2005.848627. IEEE Trans Neural Syst Rehabil Eng. 2005. PMID: 16200760 Clinical Trial.
-
Conversion of EEG activity into cursor movement by a brain-computer interface (BCI).IEEE Trans Neural Syst Rehabil Eng. 2004 Sep;12(3):331-8. doi: 10.1109/TNSRE.2004.834627. IEEE Trans Neural Syst Rehabil Eng. 2004. PMID: 15473195 Clinical Trial.
-
Brain-computer interfaces for 1-D and 2-D cursor control: designs using volitional control of the EEG spectrum or steady-state visual evoked potentials.IEEE Trans Neural Syst Rehabil Eng. 2006 Jun;14(2):225-9. doi: 10.1109/TNSRE.2006.875578. IEEE Trans Neural Syst Rehabil Eng. 2006. PMID: 16792300
-
Brain-computer interface signal processing at the Wadsworth Center: mu and sensorimotor beta rhythms.Prog Brain Res. 2006;159:411-9. doi: 10.1016/S0079-6123(06)59026-0. Prog Brain Res. 2006. PMID: 17071245 Review.
-
EMG and EOG artifacts in brain computer interface systems: A survey.Clin Neurophysiol. 2007 Mar;118(3):480-94. doi: 10.1016/j.clinph.2006.10.019. Epub 2006 Dec 13. Clin Neurophysiol. 2007. PMID: 17169606 Review.
Cited by
-
Characterizing multivariate decoding models based on correlated EEG spectral features.Clin Neurophysiol. 2013 Jul;124(7):1297-302. doi: 10.1016/j.clinph.2013.01.015. Epub 2013 Mar 7. Clin Neurophysiol. 2013. PMID: 23466267 Free PMC article.
-
Volitional control of single-electrode high gamma local field potentials by people with paralysis.J Neurophysiol. 2019 Apr 1;121(4):1428-1450. doi: 10.1152/jn.00131.2018. Epub 2019 Feb 20. J Neurophysiol. 2019. PMID: 30785814 Free PMC article. Clinical Trial.
-
Neurorehabilitation therapy of patients with severe stroke based on functional electrical stimulation commanded by a brain computer interface.J Rehabil Assist Technol Eng. 2018 Sep 28;5:2055668318789280. doi: 10.1177/2055668318789280. eCollection 2018 Jan-Dec. J Rehabil Assist Technol Eng. 2018. PMID: 31191948 Free PMC article.
-
Brain-computer interfaces and communication in paralysis: extinction of goal directed thinking in completely paralysed patients?Clin Neurophysiol. 2008 Nov;119(11):2658-66. doi: 10.1016/j.clinph.2008.06.019. Epub 2008 Sep 27. Clin Neurophysiol. 2008. PMID: 18824406 Free PMC article.
-
Brain-Computer Interfaces for Communication and Control.Commun ACM. 2011;54(5):60-66. doi: 10.1145/1941487.1941506. Commun ACM. 2011. PMID: 21984822 Free PMC article. No abstract available.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials