Purpose: To determine whether critical flicker/fusion (CFF) thresholds fulfill the criteria for a potential vision test (PVT) by being unaffected by media opacity yet affected by retinal disease.
Methods: CFF thresholds for three different stimulus sizes (0.5, 1.0, and 1.5 degrees ) were measured in 72 patients (mean age, 78.43 +/- 7.07 years) comprising 31 subjects with media opacity, 21 with macular disease, and 20 with pseudophakia.
Results: There were no statistically significant differences between CFF values from the media opacity and the pseudophakia groups for any target size (p > 0.10). However, CFF values were significantly lower in patients with macular disease for all the target sizes (p < 0.05). Analysis of a subset of six subjects with media opacity and seven subjects with macular disease and visual acuity of 20/200 or worse showed the media opacity group still had similar CFF values as the pseudophakia group and had significantly higher CFF than the macular disease group.
Conclusions: CFF testing is shown to fulfill the requirements for a PVT and may prove to be particularly useful for patients with dense media opacity.
Similar articles
-
[Practical significance of critical fusion frequency (CFF). Chronological resolution of the visual system in differential diagnosis].Ophthalmologe. 2010 Aug;107(8):715-9. doi: 10.1007/s00347-010-2214-8. Ophthalmologe. 2010. PMID: 20533042 Review. German.
-
Critical flicker fusion test of potential vision.J Cataract Refract Surg. 2007 Feb;33(2):232-9. doi: 10.1016/j.jcrs.2006.10.042. J Cataract Refract Surg. 2007. PMID: 17276263
-
Critical flicker frequency as a potential vision technique in the presence of cataracts.Invest Ophthalmol Vis Sci. 2005 Mar;46(3):1107-12. doi: 10.1167/iovs.04-1138. Invest Ophthalmol Vis Sci. 2005. PMID: 15728572
-
Capabilities of potential vision test measurements: clinical evaluation in the presence of cataract or macular disease.J Cataract Refract Surg. 2006 Jul;32(7):1151-60. doi: 10.1016/j.jcrs.2006.01.111. J Cataract Refract Surg. 2006. PMID: 16857502 Clinical Trial.
-
[Critical flicker fusion frequency in psychopathology and psychopharmacology. Review of the literature].Acta Psychiatr Belg. 1982 Jan-Feb;82(1):7-112. Acta Psychiatr Belg. 1982. PMID: 6751024 Review. French.
Cited by
-
[Practical significance of critical fusion frequency (CFF). Chronological resolution of the visual system in differential diagnosis].Ophthalmologe. 2010 Aug;107(8):715-9. doi: 10.1007/s00347-010-2214-8. Ophthalmologe. 2010. PMID: 20533042 Review. German.
-
Trichromatic critical flicker frequency as potential visual test in cataract and macula disease patients.Graefes Arch Clin Exp Ophthalmol. 2024 Jul;262(7):2171-2179. doi: 10.1007/s00417-024-06398-w. Epub 2024 Feb 8. Graefes Arch Clin Exp Ophthalmol. 2024. PMID: 38329529
-
Predictions of postoperative visual outcome in subjects with cataract: a preoperative and postoperative study.Br J Ophthalmol. 2007 May;91(5):638-43. doi: 10.1136/bjo.2006.093401. Epub 2006 Nov 23. Br J Ophthalmol. 2007. PMID: 17124240 Free PMC article.
-
Human sensory-evoked responses differ coincident with either "fusion-memory" or "flash-memory", as shown by stimulus repetition-rate effects.BMC Neurosci. 2006 Feb 23;7:18. doi: 10.1186/1471-2202-7-18. BMC Neurosci. 2006. PMID: 16504094 Free PMC article.
-
Evaluation of Critical Flicker-Fusion Frequency Measurement Methods for the Investigation of Visual Temporal Resolution.Sci Rep. 2017 Nov 15;7(1):15621. doi: 10.1038/s41598-017-15034-z. Sci Rep. 2017. PMID: 29142231 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical