Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2004 Dec;122(12):1760-6.
doi: 10.1001/archopht.122.12.1760.

A randomized trial of the effects of rigid contact lenses on myopia progression

Affiliations
Clinical Trial

A randomized trial of the effects of rigid contact lenses on myopia progression

Jeffrey J Walline et al. Arch Ophthalmol. 2004 Dec.

Abstract

Objective: To compare the effects of rigid gas-permeable contact lenses (RGPs) and soft contact lenses (SCLs) on myopia progression in children.

Methods: We randomly assigned 116 subjects to wear RGPs or SCLs. Subjects underwent cycloplegic autorefraction, keratometry, and A-scan ultrasonographic axial length measurements at each annual visit. All analyses were conducted according to the original randomization assignment. The primary outcome measure was the 3-year change in spherical equivalent cycloplegic autorefraction.

Results: The mean +/- SD spherical equivalent cycloplegic refractive error progressed -1.56 +/- 0.95 diopters (D) for RGP wearers and -2.19 +/- 0.89 D for the SCL wearers during the 3 years of the study (analysis of covariance [ANCOVA], P<.001). The axial growth of the eyes was not significantly different between treatment groups (ANCOVA, P = .57). The steep corneal meridian of the RGP wearers steepened 0.62 +/- 0.60 D, and that of the SCL wearers steepened 0.88 +/- 0.57 D during the 3 years (ANCOVA, P = .01).

Conclusions: The RGP wearers' myopia progressed less than that of the SCL wearers. The corneal curvature of the SCL wearers steepened more than that of the RGP wearers, but the axial growth was not significantly different between the groups. Most refractive error treatment effect was limited to the first year of the trial. The results of the study provide information for eye care practitioners to share with their patients, but they do not indicate that RGPs should be prescribed primarily for myopia control.

PubMed Disclaimer

Comment in

  • Contact lenses alter corneal curvature.
    Davidorf JM. Davidorf JM. Arch Ophthalmol. 2005 Oct;123(10):1455; author reply 1455. doi: 10.1001/archopht.123.10.1455-a. Arch Ophthalmol. 2005. PMID: 16219751 No abstract available.

Publication types