Sensitivity to interaural level and envelope time differences of two bilateral cochlear implant listeners using clinical sound processors
- PMID: 15599195
- DOI: 10.1097/01.aud.0000145124.85517.e8
Sensitivity to interaural level and envelope time differences of two bilateral cochlear implant listeners using clinical sound processors
Abstract
Objectives: To assess the sensitivity of two bilateral cochlear implant users to interaural level and time differences (ILDs and ITDs) for various signals presented through the auxiliary inputs of clinical sound processors that discard fine timing information and only preserve envelope cues.
Design: In a lateralization discrimination experiment, the just noticeable difference (JND) for ILDs and envelope ITDs was measured by means of an adaptive 2-AFC method. Different stimuli were used, including click trains at varying repetition rates, a speech fragment, and noise bursts. For one cochlear implant listener and one stimulus, the sensitivity to envelope ITDs was also determined with the method of constant stimuli. The dependency of ILD-JNDs on the interaural place difference was studied with stimulation at single electrode pairs by using sinusoidal input signals in combination with appropriate single-channel processor fittings. In a lateralization position experiment, subjects were required to use a visual pointer on a computer screen to indicate in-the-head positions for blocks of stimuli containing either ILD or ITD cues. All stimuli were loudness balanced (before applying ILD) and fed directly into the auxiliary inputs of the BTE processors (TEMPO+, Med-El Corp.). The automatic gain control and the processors' microphones were deactivated.
Results: Both cochlear implant listeners were highly sensitive to ILDs in all broadband stimuli used; JNDs approached those of normal-hearing listeners. Pitch-matched single electrode pairs showed significantly lower ILD-JNDs than pitch-mismatched electrode pairs. Envelope ITD-JNDs of cochlear implant listeners obtained with the adaptive method were substantially higher and showed a higher test-retest variability than waveform ITD-JNDs of normal-hearing control listeners and envelope ITD-JNDs of normal-hearing listeners reported in the literature for comparable signals. The envelope ITD-JNDs for the click trains were significantly lower than for the speech token or the noise bursts. The best envelope ITD-JND measured was ca. 250 mus for the click train at 100 cycles per sec. Direct measurement of the psychometric function for envelope ITD by the method of constant stimuli showed discrimination above chance level down to 150 micros. The lateralization position experiment showed that both ILDs and envelope ITDs can lead to monotonic changes in lateral percept.
Conclusions: The two cochlear implant users tested showed strong effects of ILDs in various broadband stimuli with respect to JNDs as well as lateralization position. The high dependency of ILD-JNDs on the interaural pitch difference suggests the potential importance of pitch-matched assignment of electrodes in the two ears by the speech processors. Envelope ITDs appear to be more ambiguous cues than ILDs, as reflected by the higher and more variable JNDs compared with normal-hearing listeners. The envelope ITD-JNDs of cochlear implant listeners depended on the stimulus.
Similar articles
-
Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users.Ear Hear. 2015 May-Jun;36(3):e62-8. doi: 10.1097/AUD.0000000000000135. Ear Hear. 2015. PMID: 25565660 Free PMC article.
-
Sound-direction identification, interaural time delay discrimination, and speech intelligibility advantages in noise for a bilateral cochlear implant user.Ear Hear. 2002 Apr;23(2):137-49. doi: 10.1097/00003446-200204000-00006. Ear Hear. 2002. PMID: 11951849
-
Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners.J Assoc Res Otolaryngol. 2022 Feb;23(1):119-136. doi: 10.1007/s10162-021-00821-3. Epub 2021 Nov 23. J Assoc Res Otolaryngol. 2022. PMID: 34812980 Free PMC article.
-
Perception and coding of interaural time differences with bilateral cochlear implants.Hear Res. 2015 Apr;322:138-50. doi: 10.1016/j.heares.2014.10.004. Epub 2014 Oct 19. Hear Res. 2015. PMID: 25456088 Review.
-
Bilateral cochlear implants in children: Effects of auditory experience and deprivation on auditory perception.Hear Res. 2016 Aug;338:76-87. doi: 10.1016/j.heares.2016.01.003. Epub 2016 Jan 30. Hear Res. 2016. PMID: 26828740 Free PMC article. Review.
Cited by
-
Interaural time discrimination of envelopes carried on high-frequency tones as a function of level and interaural carrier mismatch.Ear Hear. 2008 Oct;29(5):674-83. doi: 10.1097/AUD.0b013e3181775e03. Ear Hear. 2008. PMID: 18596646 Free PMC article.
-
Improving Interaural Time Difference Sensitivity Using Short Inter-pulse Intervals with Amplitude-Modulated Pulse Trains in Bilateral Cochlear Implants.J Assoc Res Otolaryngol. 2020 Feb;21(1):105-120. doi: 10.1007/s10162-020-00743-6. Epub 2020 Feb 10. J Assoc Res Otolaryngol. 2020. PMID: 32040655 Free PMC article.
-
Binaural-cue reweighting induced by discrimination training.Atten Percept Psychophys. 2025 Jul;87(5):1788-1800. doi: 10.3758/s13414-025-03082-x. Epub 2025 May 14. Atten Percept Psychophys. 2025. PMID: 40369364 Free PMC article.
-
Simulation of ITD-Dependent Single-Neuron Responses Under Electrical Stimulation and with Amplitude-Modulated Acoustic Stimuli.J Assoc Res Otolaryngol. 2022 Aug;23(4):535-550. doi: 10.1007/s10162-021-00823-1. Epub 2022 Mar 25. J Assoc Res Otolaryngol. 2022. PMID: 35334001 Free PMC article.
-
Synaptic plasticity after chemical deafening and electrical stimulation of the auditory nerve in cats.J Comp Neurol. 2010 Apr 1;518(7):1046-63. doi: 10.1002/cne.22262. J Comp Neurol. 2010. PMID: 20127807 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical