Can body volume be determined by PET?
Abstract
Purpose: To avoid dependence on body weight, the standardised uptake value (SUV) in positron emission tomography (PET) can instead be normalised to the lean body mass (LBM), which can be determined from body volume and mass. This study was designed to answer the following questions: Firstly, can the total body volume in principle be determined using PET? Secondly, is the precision of this measurement comparable to that achieved using an established standard method.
Methods: Ten patients were examined during oncological whole-body PET examinations. The whole-body volume of the patients was determined from the transmission scan in PET. Air displacement plethysmography with BOD POD was used for comparison as the standard method of volume determination.
Results: In all patients, the whole-body volumes could be determined using PET and the standard method. Bland and Altman [23] analysis for agreement between the volumes determined by the two methods (presentation of differences vs means) revealed a very small difference of -0.14 l. With a mean patient volume of 71.81+/-15.93 l, the relative systematic error is only <0.1%. On this basis, equality of the volume values determined by the two methods can be assumed.
Conclusion: PET can be used as a supplementary method for experimental determination of whole-body volume and total body fat in tumour patients. The fat content can be used to calculate the LBM and to determine body weight-independent SUVs (SUV(LBM)).
Similar articles
-
Comparison of different SUV-based methods for monitoring cytotoxic therapy with FDG PET.Eur J Nucl Med Mol Imaging. 2004 Nov;31(11):1471-8. doi: 10.1007/s00259-004-1626-6. Epub 2004 Jul 15. Eur J Nucl Med Mol Imaging. 2004. PMID: 15257418
-
Defining a radiotherapy target with positron emission tomography.Int J Radiat Oncol Biol Phys. 2004 Nov 15;60(4):1272-82. doi: 10.1016/j.ijrobp.2004.06.254. Int J Radiat Oncol Biol Phys. 2004. PMID: 15519800
-
Correlation of simultaneously acquired diffusion-weighted imaging and 2-deoxy-[18F] fluoro-2-D-glucose positron emission tomography of pulmonary lesions in a dedicated whole-body magnetic resonance/positron emission tomography system.Invest Radiol. 2013 May;48(5):247-55. doi: 10.1097/RLI.0b013e31828d56a1. Invest Radiol. 2013. PMID: 23519008
-
Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies.Eur J Nucl Med Mol Imaging. 2002 Dec;29(12):1630-8. doi: 10.1007/s00259-002-0974-3. Epub 2002 Oct 10. Eur J Nucl Med Mol Imaging. 2002. PMID: 12458398
-
An update on novel quantitative techniques in the context of evolving whole-body PET imaging.PET Clin. 2015 Jan;10(1):45-58. doi: 10.1016/j.cpet.2014.09.004. Epub 2014 Nov 22. PET Clin. 2015. PMID: 25455879 Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources