Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions
- PMID: 15603821
- DOI: 10.1016/j.biomaterials.2004.07.070
Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions
Abstract
The polyethylene (PE) for hip implants presents serious clinical problems; the production of debris may induce adverse tissue reactions that may lead to extensive bone loss around the implant and consequently osteolysis and implant loosening. Several attempts have been made to improve the wear properties of ultra-high molecular weight polyethylene (UHMWPE). More recently the attention of various researchers has been focused on cross-linked polyethylene (XLPE), due to its improved wear resistance with respect to conventional UHMWPE. This study was aimed at comparing the wear performances of clinically available acetabular liners (Zimmer Inc.) made of electron beam XLPE and conventional UHMWPE. To evaluate the influence of the material properties on wear, conventional UHMWPE and XLPE acetabular cups were tested against deliberately scratched CoCrMo femoral heads (Ra = 0.12-0.14 microm) in a hip joint wear simulator run for 3 million cycles with bovine calf serum as lubricant. Gravimetric measurements revealed significant differences between the wear behaviours of the two sets of acetabular cups: XLPE exhibited a wear rate about 40 times lower than conventional UHMWPE. Raman spectroscopy coupled to partial least-squares analysis was used to evaluate the possible crystallinity changes induced by mechanical stress (and thus the material wear resistance): only the UHMWPE cup which showed the highest weight loss displayed significant crystallinity changes. These results were correlated to the thickness of the plasticity-induced damage layer. The wear debris produced during the tests were isolated according to a validated protocol and imaged by scanning electron microscopy . The wear particles produced by XLPE were smaller than those produced by UHMWPE; the latter were observed as fibrillar and agglomerated particles. The mean equivalent circle diameter was 0.71 and 0.26 microm for UHMWPE and XLPE, respectively.
Similar articles
-
Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator.Biomacromolecules. 2006 Jun;7(6):1912-20. doi: 10.1021/bm060007u. Biomacromolecules. 2006. PMID: 16768414
-
A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.J Arthroplasty. 2001 Dec;16(8):1018-23. doi: 10.1054/arth.2001.27234. J Arthroplasty. 2001. PMID: 11740757
-
Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.J Biomed Mater Res. 2002;63(6):848-53. doi: 10.1002/jbm.10471. J Biomed Mater Res. 2002. PMID: 12418033
-
Implant wear mechanisms--basic approach.Biomed Mater. 2008 Dec;3(4):042001. doi: 10.1088/1748-6041/3/4/042001. Epub 2008 Sep 25. Biomed Mater. 2008. PMID: 18824778 Review.
-
New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.Acta Orthop Suppl. 2005 Feb;76(315):3-82. Acta Orthop Suppl. 2005. PMID: 15790289 Review.
Cited by
-
Characteristics of highly cross-linked polyethylene wear debris in vivo.J Biomed Mater Res B Appl Biomater. 2013 Apr;101(3):467-75. doi: 10.1002/jbm.b.32902. Epub 2013 Feb 22. J Biomed Mater Res B Appl Biomater. 2013. PMID: 23436587 Free PMC article.
-
Third body damage and wear in arthroplasty bearing materials: A review of laboratory methods.Biomater Biosyst. 2021 Sep 6;4:100028. doi: 10.1016/j.bbiosy.2021.100028. eCollection 2021 Dec. Biomater Biosyst. 2021. PMID: 36824573 Free PMC article. Review.
-
Does the addition of vitamin E to conventional UHMWPE improve the wear performance of hip acetabular cups? Micro-Raman characterization of differently processed polyethylene acetabular cups worn on a hip joint simulator.Braz J Med Biol Res. 2020;53(10):e9930. doi: 10.1590/1414-431x20209930. Epub 2020 Aug 17. Braz J Med Biol Res. 2020. PMID: 32813853 Free PMC article.
-
Quantitative Measurements of Backside Wear in Acetabular Hip Joint Replacement: Conventional Polyethylene Versus Cross-Linked Polyethylene.Materials (Basel). 2020 Apr 15;13(8):1854. doi: 10.3390/ma13081854. Materials (Basel). 2020. PMID: 32326506 Free PMC article.
-
Wear Assessment of Tibial Inserts Made of Highly Cross-Linked Polyethylene Supplemented with Dodecyl Gallate in the Total Knee Arthroplasty.Polymers (Basel). 2021 Jun 2;13(11):1847. doi: 10.3390/polym13111847. Polymers (Basel). 2021. PMID: 34199509 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources