In vivo measurements of EPR signals in whole human teeth
- PMID: 15607446
- DOI: 10.1016/j.apradiso.2004.08.042
In vivo measurements of EPR signals in whole human teeth
Abstract
Low-frequency EPR has the potential advantage of making accurate and sensitive measurements of absorbed radiation dose in teeth in situ. We report here on measurements within the human mouth in volunteers using 1200 MHz EPR, with an irradiated tooth in a special holder. We obtained a signal/noise ratio within 50% of that seen when the same sample was measured extraorally. The intraoral signal/noise can be improved and can be reduced further with optimization of conditions and use of more specifically designed and optimized resonators that fit within the mouth, probing 1-4 teeth, and can make the measurements in molars or incisors. The presence of amalgam fillings did not significantly impact the accuracy of measurements in those teeth or in adjacent teeth. These initial results make us optimistic that intra-oral measurements of the teeth will be feasible for accurate determination of exposures over the whole range in which acute clinical effects are possible.
Similar articles
-
Differentiation of the observed low frequency (1200MHz) EPR signals in whole human teeth.Appl Radiat Isot. 2005 Feb;62(2):133-9. doi: 10.1016/j.apradiso.2004.08.038. Appl Radiat Isot. 2005. PMID: 15607439
-
Spectrum file size optimization for EPR tooth dosimetry.Appl Radiat Isot. 2005 Feb;62(2):197-200. doi: 10.1016/j.apradiso.2004.08.040. Appl Radiat Isot. 2005. PMID: 15607448
-
Retrospective radiation dosimetry using electron paramagnetic resonance in canine dental enamel.Appl Radiat Isot. 2005 Feb;62(2):173-9. doi: 10.1016/j.apradiso.2004.08.031. Appl Radiat Isot. 2005. PMID: 15607444
-
In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionising radiation.Radiat Prot Dosimetry. 2006;120(1-4):163-70. doi: 10.1093/rpd/nci554. Epub 2006 Apr 27. Radiat Prot Dosimetry. 2006. PMID: 16644994 Review.
-
Retrospective assessment of radiation exposure using biological dosimetry: chromosome painting, electron paramagnetic resonance and the glycophorin a mutation assay.Radiat Res. 2006 Jul;166(1 Pt 2):287-302. doi: 10.1667/RR3273.1. Radiat Res. 2006. PMID: 16808614 Review.
Cited by
-
Factors Affecting the Quality of Tooth Enamel for In Vivo EPR-Based Retrospective Biodosimetry.Radiat Prot Dosimetry. 2016 Dec;172(1-3):96-102. doi: 10.1093/rpd/ncw212. Epub 2016 Jul 29. Radiat Prot Dosimetry. 2016. PMID: 27473693 Free PMC article. Review.
-
Experimental Procedures for Sensitive and Reproducible In Situ EPR Tooth Dosimetry.Radiat Meas. 2007 Jul;42(6-7):1094-1098. doi: 10.1016/j.radmeas.2007.05.001. Radiat Meas. 2007. PMID: 18591989 Free PMC article.
-
Development of in vivo tooth EPR for individual radiation dose estimation and screening.Health Phys. 2010 Feb;98(2):327-38. doi: 10.1097/HP.0b013e3181a6de5d. Health Phys. 2010. PMID: 20065702 Free PMC article.
-
A Coaxial Dielectric Probe Technique for Distinguishing Tooth Enamel from Dental Resin.Adv Biomed Eng Res. 2015;3:8-17. doi: 10.14355/aber.2015.03.002. Adv Biomed Eng Res. 2015. PMID: 27182531 Free PMC article.
-
Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation.Int J Radiat Biol. 2011 Aug;87(8):766-75. doi: 10.3109/09553002.2011.583316. Epub 2011 Jun 23. Int J Radiat Biol. 2011. PMID: 21696339 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources