Measurements of clinically significant doses of ionizing radiation using non-invasive in vivo EPR spectroscopy of teeth in situ
- PMID: 15607464
- DOI: 10.1016/j.apradiso.2004.08.016
Measurements of clinically significant doses of ionizing radiation using non-invasive in vivo EPR spectroscopy of teeth in situ
Abstract
There are plausible circumstances in which populations potentially have been exposed to doses of ionizing radiation that could cause direct clinical effects within days or weeks, but there is no clear knowledge as to the magnitude of the exposure to individuals. In vivo EPR is a method, perhaps the only such method that can differentiate among doses sufficiently to classify individuals into categories for treatment with sufficient accuracy to facilitate decisions on medical treatment. Individuals with significant risk then can have appropriate procedures initiated immediately, while those without a significant probability of acute effects could be reassured and removed from the need for further medical treatment. In its current state, the in vivo EPR dosimeter can provide estimates of absorbed dose of +/-25 cGy in the range of 100-->1000 cGy. This is expected to improve, with improvements in the resonator, the algorithm for calculating dose, and the uniformity of the magnetic field. In its current state of development, it probably is sufficient for most applications related to terrorism or nuclear warfare, for decision-making for action for individuals in regard to acute effects from exposure to ionizing radiation.
Similar articles
-
In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionising radiation.Radiat Prot Dosimetry. 2006;120(1-4):163-70. doi: 10.1093/rpd/nci554. Epub 2006 Apr 27. Radiat Prot Dosimetry. 2006. PMID: 16644994 Review.
-
In vivo measurements of EPR signals in whole human teeth.Appl Radiat Isot. 2005 Feb;62(2):187-90. doi: 10.1016/j.apradiso.2004.08.042. Appl Radiat Isot. 2005. PMID: 15607446 Clinical Trial.
-
Spectrum file size optimization for EPR tooth dosimetry.Appl Radiat Isot. 2005 Feb;62(2):197-200. doi: 10.1016/j.apradiso.2004.08.040. Appl Radiat Isot. 2005. PMID: 15607448
-
Estimation of radiation levels by EPR measurement of tooth enamel in Indian populations.Appl Radiat Isot. 2005 Feb;62(2):207-11. doi: 10.1016/j.apradiso.2004.08.010. Appl Radiat Isot. 2005. PMID: 15607450
-
Radiation shielding technology.Health Phys. 2005 Apr;88(4):297-322. Health Phys. 2005. PMID: 15761292 Review.
Cited by
-
A critical assessment of biodosimetry methods for large-scale incidents.Health Phys. 2010 Feb;98(2):95-108. doi: 10.1097/HP.0b013e3181b8cffd. Health Phys. 2010. PMID: 20065671 Free PMC article.
-
The view from the trenches: part 2-technical considerations for EPR screening.Health Phys. 2010 Feb;98(2):128-35. doi: 10.1097/01.HP.0000348461.00071.10. Health Phys. 2010. PMID: 20065674 Free PMC article.
-
Surface loop resonator design for in vivo EPR tooth dosimetry using finite element analysis.Health Phys. 2010 Feb;98(2):339-44. doi: 10.1097/HP.0b013e3181a6dd08. Health Phys. 2010. PMID: 20065703 Free PMC article.
-
Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation.Int J Radiat Biol. 2011 Aug;87(8):766-75. doi: 10.3109/09553002.2011.583316. Epub 2011 Jun 23. Int J Radiat Biol. 2011. PMID: 21696339 Free PMC article.
-
EPR Everywhere.Appl Magn Reson. 2021;52(8):1113-1139. doi: 10.1007/s00723-020-01304-z. Epub 2021 Jan 24. Appl Magn Reson. 2021. PMID: 33519097 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical