. 2005 Feb;59(2):152-5.
doi: 10.1016/j.jhin.2004.09.009.

Predictive value of the user seal check in determining half-face respirator fit

Affiliations

Predictive value of the user seal check in determining half-face respirator fit

J L Derrick et al. J Hosp Infect. 2005 Feb.

Abstract

Guidelines issued by the Centers for Disease Control and Prevention and the World Health Organization state that healthcare workers should wear N95 masks or higher-level protection during all contact with suspected cases of severe acute respiratory syndrome. Before use, the manufacturer recommends performing a user seal check to ensure that the mask is fitted correctly. This study aimed to test the ability of the user seal check to detect poorly fitting masks. This study is a retrospective review of a mask-fitting programme carried out in the intensive care unit of the Prince of Wales Hospital in Hong Kong. In this programme, all staff were tested with two types of N95 mask and one type of N100 mask. The results of the documented user seal check were then compared with the formal fit-test results from a PortaCount. Using a PortaCount reading of 100 as the criterion for a correctly fitted mask, the user seal check wrongly indicated that the mask fitted on 18-31% of occasions, and wrongly indicated that it did not fit on 21-40% of occasions. These data indicate that the user seal check should not be used as a surrogate fit test. Its usefulness as a pre-use test must also be questioned.

PubMed Disclaimer

References

    1. Anonymous Laboratory performance evaluation of N95 filtering facepiece respirators, 1996. MMWR. 1998;47:1045–1049. - PubMed
    1. National Institute for Occupational Safety and Health . US Department of Health and Human Services, Public Health Service, Centers for Disease Control, National Institute for Occupational Safety and Health; Morgantown, WV: 1999. TB respiratory protection program in health care facilities.
    1. Respiratory protection. Code of Federal Regulations Title 29. Part 191.134. Washington DC: Office of the Federal Register, National Archives and Records Administration; 1997.
    1. Delaney L.J., McKay R.T., Freeman A. Determination of known exhalation valve damage using a negative pressure user seal check method on full facepiece respirators. Appl Occup Environ Hyg. 2003;18:237–243. - PubMed
    1. Sreenath A., Weed J., Church T. A modified protocol for quantitative fit testing using the PortaCount. Appl Occup Environ Hyg. 2001;16:979–988. - PubMed

MeSH terms