Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2005 Feb;15(2):220-8.
doi: 10.1007/s00330-004-2570-3. Epub 2004 Dec 29.

Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

Affiliations
Comparative Study

Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

Young Kon Kim et al. Eur Radiol. 2005 Feb.

Abstract

The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (Gd-BOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.

PubMed Disclaimer

References

    1. Acad Radiol. 1998 Apr;5 Suppl 1:S86-9; discussion S93-4 - PubMed
    1. Eur Radiol. 2003 Feb;13(2):262-72 - PubMed
    1. Radiology. 1989 Apr;171(1):47-51 - PubMed
    1. Eur Radiol. 2004 Jan;14(1):5-13 - PubMed
    1. Radiology. 1995 Aug;196 (2):481-8 - PubMed

Publication types

MeSH terms

LinkOut - more resources