Comparative Study
. 2005 Jan;46(1):176-83.

Effect of perfusion pattern and imaging sequence on gated perfusion SPECT evaluation of myocardial stunning

Affiliations
  • PMID: 15632050
Free article
Comparative Study

Effect of perfusion pattern and imaging sequence on gated perfusion SPECT evaluation of myocardial stunning

Alain Manrique et al. J Nucl Med. 2005 Jan.
Free article

Abstract

The aim of this study was to determine the effect of perfusion defect and imaging sequence on the evaluation of myocardial stunning with gated perfusion SPECT.

Methods: A dynamic mathematic cardiac torso phantom was used to create 100 gated SPECT simulations (50 stress-rest and 50 rest-stress sequences) with a wide range of perfusion defects. No segmental wall motion abnormalities were created. After generating projection images, 2 additional acquisitions were simulated by thresholding the projected data to 25% and 75% of the maximum. Finally, gated SPECT projections were grouped by 2s to generate 2 series of phantoms corresponding to stress-rest and rest-stress imaging sequences. For each sequence, the first dataset was the 25% thresholded gated SPECT. Both 75% thresholded and 100% signal intensity were used as a second dataset. Each simulated gated SPECT image differed from others in the extent of myocardial scar or ischemia, but all had the same end-diastolic volume (EDV) (125 mL), end-systolic volume (ESV) (48 mL), and ejection fraction (EF) (62%). Left ventricular perfusion and function were each assessed using validated software.

Results: Mean stress EDV was decreased when compared with rest-simulated data (111 +/- 4.7 and 112.4 +/- 4.8 mL, respectively; P < or = 0.05), and mean stress ESV was increased when compared with rest-simulated data (44 +/- 4.2 and 42.7 +/- 4 mL, respectively; P < 0.02). The resulting mean stress EF was decreased in the same comparison (60.3% +/- 3.1% and 62% +/- 2.7%, respectively; P = 0.0001). After multivariate analysis, the difference between stress and rest EF was significantly influenced by myocardial infarction (P = 0.0027), severe extent of myocardial ischemia (P = 0.0017), and imaging sequence (P < 0.0001). A > or =5% decrease in EF on stress SPECT (i.e., myocardial stunning) was significantly associated with the stress-rest sequence (chi(2) = 26; P < 0.0001).

Conclusion: Perfusion defects and imaging sequence had significant effects on the evaluation of myocardial stunning using gated perfusion SPECT.