Simultaneous determination of morphine, oxycodone, morphine-3-glucuronide, and noroxycodone concentrations in rat serum by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry
- PMID: 15639445
- DOI: 10.1016/j.jchromb.2004.10.035
Simultaneous determination of morphine, oxycodone, morphine-3-glucuronide, and noroxycodone concentrations in rat serum by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry
Abstract
An assay using high performance liquid chromatography (HPLC)-electrospray ionization-tandem mass spectrometry (ESI-MS-MS) was developed for simultaneously determining concentrations of morphine, oxycodone, morphine-3-glucuronide, and noroxycodone, in 50 microl samples of rat serum. Deuterated (d(3)) analogues of each compound were used as internal standards. Samples were treated with acetonitrile to precipitate plasma proteins; acetonitrile was removed from the supernatant by centrifugal evaporation before analysis. Limits of quantitation (ng/ml) and their between-day accuracy and precision (%deviation and %CV) were--morphine, 3.8 (4.3% and 7.6%); morphine-3-glucuronide, 5.0 (4.5% and 2.9%); oxycodone, 4.5 (0.4% and 9.3%); noroxycodone, 5.0 (8.5% and 4.6%).
MeSH terms
Substances
LinkOut - more resources
Full Text Sources