Comparative Study
. 2005 Feb;55(2):157-61.
doi: 10.1093/jac/dkh514. Epub 2005 Jan 13.

Evaluation of cefoxitin 5 and 10 microg discs for the detection of methicillin resistance in staphylococci

Affiliations
Comparative Study

Evaluation of cefoxitin 5 and 10 microg discs for the detection of methicillin resistance in staphylococci

R Skov et al. J Antimicrob Chemother. 2005 Feb.

Abstract

Objective: To evaluate cefoxitin 5 and 10 microg discs for detection of methicillin resistance in staphylococci.

Methods: Six hundred and forty-one Staphylococcus aureus (261 mecA-negative and 380 mecA-positive) and 344 coagulase-negative staphylococci (CoNS) (132 mecA-negative and 212 mecA-positive) were investigated. The CoNS represented nine species, Staphylococcus epidermidis being the most frequent (n = 231). All isolates were tested using semi-confluent growth on Iso-Sensitest agar (ISA), and Mueller-Hinton agar (MH) using a 5 and a 10 microg cefoxitin disc and overnight incubation in ambient air at 35-37 degrees C.

Results: For S. aureus, both cefoxitin discs performed with high accuracy on both media. The sensitivity and specificity for the following proposed interpretive zone diameters were: ISA 5 microg, R < 14 mm (99.5% and 98.1%); ISA 10 microg, R < 22 mm (99.5% and 98.1%); MH 5 microg, R < 12 mm (99.7% and 98.1%); and MH 10 microg, R < 18 mm (99.5% and 98.9%), respectively. All four variants were superior to oxacillin using the former SRGA methodology. In CoNS, a substantial overlap was seen for all variants. However, by avoiding primary interpretation in the overlapping interval, highly accurate results could be obtained for 81%, 80%, 91% and 97% of the isolates, respectively.

Conclusion: For S. aureus, cefoxitin 5 and 10 microg discs performed with high accuracy on both ISA and MH using semi-confluent growth and standard incubation conditions. With the introduction of a defined interval in which primary interpretation should be avoided, the method could also be used for CoNS.