Goniometric and conoscopic measurements of angular display contrast for one-, three-, five-, and nine-million-pixel medical liquid crystal displays
- PMID: 15651628
- DOI: 10.1118/1.1824198
Goniometric and conoscopic measurements of angular display contrast for one-, three-, five-, and nine-million-pixel medical liquid crystal displays
Abstract
Active-matrix liquid crystal displays (AMLCDs) have become the preferred choice for displaying digital diagnostic images because of their low cost of ownership, high contrast, and small footprint. However, the contrast and luminance of AMLCDs changes significantly with viewing direction. In this paper, we use a goniometric and a conoscopic method to measure angular contrast and luminance in one-, three-, five-, and nine-million-pixel medical AMLCDs. The viewing angle characteristics of the displays are compared by evaluating the compliance with the desired grayscale and recommended tolerance limits. Using the measured contrast responses, we determined the angle along each of the orthogonal and diagonal axes for which the luminance ratio drops to 0.5, 0.2, and 0.1 of the maximum ratio, seen at perpendicular viewing. The results show a reduction as large as 54% in available JND levels between the perpendicular and off-normal viewing directions. All of the display systems proved to have better angular response in the horizontal and vertical direction as compared to the diagonal directions, and none were able to satisfy a 20% contrast tolerance limit for any viewing direction lying in a cone at an angle of 45 degrees from the normal. Additionally, we show that the measured contrast can be significantly affected by the measurement method used to record the angular change in luminance.
Similar articles
-
Effect of viewing angle on luminance and contrast for a five-million-pixel monochrome display and a nine-million-pixel color liquid crystal display.J Digit Imaging. 2004 Dec;17(4):264-70. doi: 10.1007/s10278-004-1021-7. J Digit Imaging. 2004. PMID: 15692870 Free PMC article.
-
Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays.Med Phys. 2003 Oct;30(10):2602-13. doi: 10.1118/1.1606449. Med Phys. 2003. PMID: 14596296
-
Comparison of conoscopic, telescopic, and goniometric methods for measuring angular emissions from medical liquid-crystal displays.Appl Opt. 2004 Sep 10;43(26):4999-5005. doi: 10.1364/ao.43.004999. Appl Opt. 2004. PMID: 15468700
-
AAPM/RSNA tutorial on equipment selection: PACS equipment overview: display systems.Radiographics. 2004 May-Jun;24(3):879-89. doi: 10.1148/rg.243035133. Radiographics. 2004. PMID: 15143237 Review.
-
High-fidelity electronic display of digital radiographs.Radiographics. 1999 Nov-Dec;19(6):1653-69. doi: 10.1148/radiographics.19.6.g99no081653. Radiographics. 1999. PMID: 10555680 Review.
Cited by
-
Digital mammography: comparative performance of color LCD and monochrome CRT displays.Acad Radiol. 2007 May;14(5):539-46. doi: 10.1016/j.acra.2007.01.022. Acad Radiol. 2007. PMID: 17434067 Free PMC article.
-
Increasing the number of gray shades in medical display systems--how much is enough?J Digit Imaging. 2007 Dec;20(4):422-32. doi: 10.1007/s10278-006-1052-3. J Digit Imaging. 2007. PMID: 17195900 Free PMC article.
-
ACR-AAPM-SIIM practice guideline for determinants of image quality in digital mammography.J Digit Imaging. 2013 Feb;26(1):10-25. doi: 10.1007/s10278-012-9521-3. J Digit Imaging. 2013. PMID: 22992865 Free PMC article. No abstract available.
-
Introduction to grayscale calibration and related aspects of medical imaging grade liquid crystal displays.J Digit Imaging. 2008 Jun;21(2):193-207. doi: 10.1007/s10278-007-9022-y. J Digit Imaging. 2008. PMID: 17333412 Free PMC article.
-
Visual assessment of angular response in medical liquid crystal displays.J Digit Imaging. 2006 Sep;19(3):240-8. doi: 10.1007/s10278-006-0633-5. J Digit Imaging. 2006. PMID: 16741662 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources