Clinical Trial
. 2005 Jan 18;45(2):212-5.
doi: 10.1016/j.jacc.2004.09.062.

Detection of embolic particles with the Doppler guide wire during coronary intervention in patients with acute myocardial infarction: efficacy of distal protection device

Affiliations
Free article
Clinical Trial

Detection of embolic particles with the Doppler guide wire during coronary intervention in patients with acute myocardial infarction: efficacy of distal protection device

Atsunori Okamura et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: We investigated whether embolic particles could be detected as high-intensity transient signals (HITS) with a Doppler guide wire during percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) We also assessed whether these signals could be reduced using a distal protection (DP) device.

Background: Embolization of thrombi and plaque components to the microcirculation is a major complication of PCI in patients with AMI. Embolic particles running in the cerebral artery are detected as HITS by transcranial Doppler ultrasound.

Methods: We prospectively studied 16 consecutive patients with AMI who underwent direct PCI within 24 h after the onset of symptoms. A PercuSurge GuardWire (MedtronicAVE, Santa Rosa, California) was used as the DP device. Eight patients were randomly assigned to the non-DP group, and the remaining eight were assigned to the DP group. Coronary flow velocity was recorded continuously from before the first balloon inflation to after balloon deflation.

Results: All patients in the non-DP group had HITS detected (12 +/- 9 counts) within five consecutive beats (4 +/- 1 beat) after balloon deflation, but none were detected in any of the patients in the DP group.

Conclusions: The Doppler guide wire can be used to visually detect and count emboli as HITS, and the DP device is effective for prevention of distal embolization.